Cargando…

Alternative Breast Imaging Four Model-Based Approaches /

Medical imaging has been transformed over the past 30 years by the advent of computerized tomography (CT), magnetic resonance imaging (MRI), and various advances in x-ray and ultrasonic techniques. An enabling force behind this progress has been the (so far) exponentially increasing power of compute...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor Corporativo: SpringerLink (Online service)
Otros Autores: Paulsen, Keith D. (Editor ), Meaney, Paul M. (Editor ), Gilman, Larry (Editor )
Formato: Electrónico eBook
Idioma:Inglés
Publicado: New York, NY : Springer US : Imprint: Springer, 2005.
Edición:1st ed. 2005.
Colección:The Springer International Series in Engineering and Computer Science ; 778
Temas:
Acceso en línea:Texto Completo

MARC

LEADER 00000nam a22000005i 4500
001 978-0-387-23364-2
003 DE-He213
005 20220118070537.0
007 cr nn 008mamaa
008 100301s2005 xxu| s |||| 0|eng d
020 |a 9780387233642  |9 978-0-387-23364-2 
024 7 |a 10.1007/b101336  |2 doi 
050 4 |a TA1634 
072 7 |a UYQV  |2 bicssc 
072 7 |a COM012000  |2 bisacsh 
072 7 |a UYQV  |2 thema 
082 0 4 |a 006.37  |2 23 
245 1 0 |a Alternative Breast Imaging  |h [electronic resource] :  |b Four Model-Based Approaches /  |c edited by Keith D. Paulsen, Paul M. Meaney, Larry Gilman. 
250 |a 1st ed. 2005. 
264 1 |a New York, NY :  |b Springer US :  |b Imprint: Springer,  |c 2005. 
300 |a XVI, 254 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a The Springer International Series in Engineering and Computer Science ;  |v 778 
505 0 |a Four Alternative Breast Imaging Modalities -- Computational Framework -- Magnetic Resonance Elastography: Theory -- Magnetic Resonance Elastrography: Experimental Validation and Performance Optimazation -- Electrical Impedance Spectroscopy: Theory -- Electrical Impedance Spectroscopy: Translation to Clinic -- Microwave Imaging: A Model-Based Approach -- Microwave Imaging: Hardware and Results -- Near Infrared Spectroscopic Imaging: Theory -- Near Infrared Spectroscopic Imaging: Translation to Clinic -- Statistical Methods for Alternative Imaging Modalities in Breast Cancer Clinical Research. 
520 |a Medical imaging has been transformed over the past 30 years by the advent of computerized tomography (CT), magnetic resonance imaging (MRI), and various advances in x-ray and ultrasonic techniques. An enabling force behind this progress has been the (so far) exponentially increasing power of computers, which has made it practical to explore fundamentally new approaches. In particular, what our group terms "model-based" modalities-which produce tissue property images from data using nonlinear, iterative numerical modeling techniques-have become increasingly feasible. Alternative Breast Imaging: Four Model-Based Approaches explores our research on four such modalities, particularly with regard to imaging of the breast: (1) MR elastography (MRE), (2) electrical impedance spectroscopy (EIS), (3) microwave imaging spectroscopy (MIS), and (4) near infrared spectroscopic imaging (NIS). Chapter 1 introduces the present state of breast imaging and discusses how our alternative modalities can contribute to the field. Chapter 2 looks at the computational common ground shared by all four modalities. Chapters 2 through 10 are devoted to the four modalities, with each modality being discussed first in a theory chapter and then in an implementation-and-results chapter. The eleventh and final chapter discusses statistical methods for image analysis in the context of these four alternative imaging modalities. Imaging for the detection of breast cancer is a particularly interesting and relevant application of the four imaging modalities discussed in this book. Breast cancer is an extremely common health problem for women; the National Cancer Institute estimates that one in eight US women will develop breast cancer at least once in her lifetime. Yet the efficacy of the standard (and notoriously uncomfortable) early-detection test, the x-ray mammogram, has been disputed of late, especially for younger women. Conditions are thus ripe for the development of affordable techniques that replace or complement mammography. The breast is both anatomically accessible and small enough that the computing power required to model it, is affordable. Alternative Breast Imaging: Four Model-Based Approaches is structured to meet the needs of a professional audience composed of researchers and practitioners in industry. This book is also suitable for graduate-level students in computer science, electrical engineering and biomedical imaging. 
650 0 |a Computer vision. 
650 0 |a Ultrasonics. 
650 0 |a Radiology. 
650 0 |a Biomedical engineering. 
650 0 |a Image processing-Digital techniques. 
650 1 4 |a Computer Vision. 
650 2 4 |a Ultrasonics. 
650 2 4 |a Radiology. 
650 2 4 |a Biomedical Engineering and Bioengineering. 
650 2 4 |a Computer Imaging, Vision, Pattern Recognition and Graphics. 
700 1 |a Paulsen, Keith D.  |e editor.  |4 edt  |4 http://id.loc.gov/vocabulary/relators/edt 
700 1 |a Meaney, Paul M.  |e editor.  |4 edt  |4 http://id.loc.gov/vocabulary/relators/edt 
700 1 |a Gilman, Larry.  |e editor.  |4 edt  |4 http://id.loc.gov/vocabulary/relators/edt 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer Nature eBook 
776 0 8 |i Printed edition:  |z 9781441936165 
776 0 8 |i Printed edition:  |z 9780387503080 
776 0 8 |i Printed edition:  |z 9780387233635 
830 0 |a The Springer International Series in Engineering and Computer Science ;  |v 778 
856 4 0 |u https://doi.uam.elogim.com/10.1007/b101336  |z Texto Completo 
912 |a ZDB-2-SCS 
912 |a ZDB-2-SXCS 
950 |a Computer Science (SpringerNature-11645) 
950 |a Computer Science (R0) (SpringerNature-43710)