|
|
|
|
LEADER |
00000cam a22000007a 4500 |
001 |
SCIDIR_on1358895951 |
003 |
OCoLC |
005 |
20231120010720.0 |
006 |
m o d |
007 |
cr |n||||||||| |
008 |
230123s2023 enk o 001 0 eng d |
040 |
|
|
|a YDX
|b eng
|c YDX
|d OPELS
|d EBLCP
|d OCLCQ
|d OCLCF
|d OCLCQ
|d OCLCO
|
020 |
|
|
|a 9780128217429
|q (electronic bk.)
|
020 |
|
|
|a 0128217421
|q (electronic bk.)
|
020 |
|
|
|z 9780128215968
|
020 |
|
|
|z 0128215968
|
035 |
|
|
|a (OCoLC)1358895951
|
050 |
|
4 |
|a RD549
|
082 |
0 |
4 |
|a 617.5810592
|2 23
|
245 |
0 |
0 |
|a Biomarkers of hip implant function /
|c edited by Ilona �Swi�atkowska.
|
260 |
|
|
|a London :
|b Academic Press,
|c 2023.
|
300 |
|
|
|a 1 online resource
|
500 |
|
|
|a Includes index.
|
588 |
0 |
|
|a Print version record.
|
505 |
0 |
|
|a Front Cover -- Biomarkers of Hip Implant Function -- Copyright Page -- Contents -- List of contributors -- I. Foundational information -- 1 Introduction to hip implants and biomarker testing -- 1.1 Overview of the hip joint -- 1.1.1 Anatomy of the hip -- 1.1.1.1 Cartilage -- 1.1.1.2 Joint capsule and synovial fluid -- 1.1.1.3 Ligaments -- 1.1.1.4 Muscles -- 1.1.1.5 Blood supply and innervation -- 1.1.2 Hip joint pathologies -- 1.1.2.1 Osteoarthritis -- 1.1.2.2 Rheumatoid arthritis -- 1.1.2.3 Hip dysplasia -- 1.1.2.4 Avascular necrosis -- 1.1.2.5 Femoroacetabular impingement
|
505 |
8 |
|
|a 1.1.2.6 Traumatic injuries -- 1.2 Overview of hip implants -- 1.2.1 Implant biomaterials -- 1.2.1.1 Metals -- 1.2.1.2 Plastic polymers -- 1.2.1.3 Ceramics -- 1.2.2 Bone fixation -- 1.2.3 Implant classification -- 1.2.4 Evolution of a total hip replacement -- 1.2.4.1 Implant modularity -- 1.2.5 The rise and fall of hip resurfacing -- 1.2.6 Implant degradation -- 1.2.7 Implant performance -- 1.2.7.1 Surgeon factors -- 1.2.7.2 Implant factors -- 1.2.7.3 Patient factors -- 1.3 Introduction to biomarkers -- 1.3.1 Biomarker discovery -- 1.3.2 Assay validation -- 1.3.3 Evaluation of clinical validity
|
505 |
8 |
|
|a 1.3.3.1 Sensitivity and specificity -- 1.3.3.2 Predictive values -- 1.3.3.3 Likelihood ratios -- 1.3.3.4 Diagnostic accuracy -- 1.3.3.5 Receiver operating characteristic curves -- 1.3.3.6 Diagnostic odds ratios -- 1.3.4 Characteristics of an ideal biomarker -- 1.3.5 Biomarkers of hip implant function and toxicity -- References -- 2 Degradation of metal hip implants -- 2.1 Introduction to metallic biomaterials -- 2.1.1 Iron-based alloys -- 2.1.2 Cobalt-based alloys -- 2.1.3 Titanium-based alloys -- 2.2 Introduction to tribology -- 2.2.1 Contact of surfaces -- 2.2.2 Friction
|
505 |
8 |
|
|a 2.2.3 Wear of materials -- 2.2.3.1 Abrasive wear -- 2.2.3.2 Adhesive wear -- 2.2.3.3 Fretting/fatigue wear -- 2.2.4 Lubrication -- 2.2.4.1 Boundary lubrication -- 2.2.4.2 Fluid-film lubrication -- 2.2.4.3 Mixed lubrication -- 2.2.4.4 Lubrication in metal hips -- 2.3 Introduction to corrosion -- 2.3.1 Thermodynamics and electrochemistry -- 2.3.2 Passivity of metallic materials -- 2.3.3 Types of corrosion -- 2.3.3.1 Uniform/general corrosion -- 2.3.3.2 Galvanic corrosion -- 2.3.3.3 Crevice corrosion -- 2.3.3.4 Pitting corrosion -- 2.3.3.5 Intergranular corrosion -- 2.4 Tribocorrosion
|
505 |
8 |
|
|a 2.5 Modern hip replacements -- 2.5.1 Sources of degradation -- 2.5.1.1 Bearing surfaces -- 2.5.1.2 Modular tapers -- 2.5.1.3 Stem-cement interface -- 2.5.2 Adverse reaction to metal debris -- 2.5.3 Assessing material loss from metal hip implants -- 2.5.4 Studying metal deposits in tissue -- 2.5.4.1 Periprosthetic tissue -- 2.5.4.2 Organ tissue -- 2.6 Summary and future directions -- References -- 3 Implant metals and their potential toxicity -- 3.1 Hip implant metals and the human health -- 3.1.1 Cobalt -- 3.1.1.1 Toxicokinetics -- 3.1.1.2 Systemic toxicity -- 3.1.2 Chromium
|
650 |
|
0 |
|a Artificial hip joints
|x Complications.
|
650 |
|
0 |
|a Artificial hip joints
|x Complications
|x Prevention.
|
650 |
|
0 |
|a Biochemical markers.
|
650 |
|
2 |
|a Biomarkers
|0 (DNLM)D015415
|
650 |
|
6 |
|a Marqueurs biologiques.
|0 (CaQQLa)201-0177920
|
650 |
|
7 |
|a Artificial hip joints
|x Complications
|2 fast
|0 (OCoLC)fst00817224
|
650 |
|
7 |
|a Biochemical markers
|2 fast
|0 (OCoLC)fst00831950
|
655 |
|
0 |
|a Electronic books.
|
700 |
1 |
|
|a �Swi�atkowska, Ilona,
|e editor.
|
776 |
0 |
8 |
|c Original
|z 0128215968
|z 9780128215968
|w (OCoLC)1201386303
|
776 |
0 |
8 |
|i Print version:
|t Biomarkers of hip implant function
|z 9780128215968
|w (OCoLC)1242819450
|
856 |
4 |
0 |
|u https://sciencedirect.uam.elogim.com/science/book/9780128215968
|z Texto completo
|