Corrosion under insultation (CUI) guidelines : technical guide for managing CUI /
Clasificación: | Libro Electrónico |
---|---|
Autor Corporativo: | |
Otros Autores: | |
Formato: | Electrónico eBook |
Idioma: | Inglés |
Publicado: |
Duxford ; Cambridge, MA :
Woodhead Publishing,
[2020]
|
Edición: | Third edition. |
Colección: | Publications (European Federation of Corrosion) ;
no. 55. |
Temas: | |
Acceso en línea: | Texto completo |
Tabla de Contenidos:
- Intro
- Corrosion Under Insulation (CUI) Guidelines: Technical Guide for Managing CUI
- Copyright
- Dedication
- Contents
- European Federation of Corrosion (EFC) publications: Series introduction
- Volumes in the EFC series list
- 1 Introduction
- 1.1 Purpose of the document
- References
- 2 Economic consideration
- 2.1 Statistical analysis
- 2.2 Size of the issue
- 2.2.1 Safety and integrity
- 2.2.2 Environment
- 2.2.3 Revenue or production loss
- 2.2.4 Reputation
- 2.2.5 Collateral damage cost
- 2.2.6 Online leak sealing cost
- 2.2.7 Repair and/or replacement, fabrication and installation costs
- 2.2.8 Fitness for continued service
- 2.2.9 On-stream inspection and non-destructive examination and testing
- 2.3 Key performance indicators
- 3 Ownership and responsibility
- 3.1 Senior management
- 3.2 Engineering manager
- 3.3 Maintenance
- 3.4 Operations
- 3.5 Inspection
- 3.6 Members of a project team
- Corrosion-under-insulation program
- 3.7 Engineering and EPC(m)
- 4 The risk-based inspection methodology for CUI
- 4.1 Introduction
- 4.2 High-level prioritization
- 4.2.1 Health & safety consequences (A)
- 4.2.2 Environmental consequences (B)
- 4.2.3 Economic consequences (C)
- 4.2.4 Impact on reputation (D)
- 4.3 Data validation
- 4.3.1 The need for data validation
- 4.3.2 Different aspects of a data validation
- 4.3.3 Implementation of data validation
- 4.3.4 CUI and mothballing of equipment
- 4.4 Challenging the need for insulation
- 4.5 Using RBI to design CUI inspection plans
- 4.5.1 Preparation of an RBI analysis
- 4.5.2 Susceptibility factors
- 4.5.2.1 Operating temperature
- 4.5.2.2 Coating status
- 4.5.2.3 Cladding/insulation condition
- 4.5.2.4 Available corrosion allowance
- 4.5.2.5 External coil/steam tracing
- 4.5.2.6 External environment
- 4.5.3 Qualitative RBI analysis
- 4.5.4 Semiquantitative RBI analysis
- 4.5.4.1 Consequence of CUI failure
- 4.5.4.2 Probability of CUI failure
- 4.5.4.3 Risk of CUI failure
- 5 Inspection activities and strategy
- 5.1 General considerations
- 5.2 Typical locations on piping circuits susceptible to corrosion-under-insulation
- 5.3 Typical locations on equipment susceptible to corrosion-under-insulation
- 5.3.1 Vessels, columns and tanks
- 5.3.2 Heat exchangers
- 5.4 Examples of a risk-based inspection plan
- 5.4.1 Evaluated risk level: High-extreme
- 5.4.2 Evaluated risk level: Medium-high
- 5.4.3 Evaluated risk level: Medium
- 5.4.4 Evaluated risk level: Low
- 5.4.5 Evaluated risk level: Negligible
- 6 Non-destructive examination and testing screening techniques for corrosion-under-insulation
- 6.1 Non-destructive examination and testing techniques
- Reference
- 7 Recommended best practice to mitigate CUI
- 7.1 Background
- 7.1.1 Key parameters
- 7.1.2 Assumptions