Cargando…

Mass spectrometry for the clinical laboratory.

Mass Spectrometry for the Clinical Laboratory is an accessible guide to mass spectrometry and the development, validation, and implementation of the most common assays seen in clinical labs. It provides readers with practical examples for assay development, and experimental design for validation to...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Otros Autores: Nair, Hari, Clarke, William, 1970-
Formato: Electrónico eBook
Idioma:Inglés
Publicado: [Amsterdam] : Elsevier Ltd. : Academic Press, [2017]
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 i 4500
001 SCIDIR_ocn962412307
003 OCoLC
005 20231120112151.0
006 m o d
007 cr |||||||||||
008 161109s2017 ne ob 001 0 eng d
040 |a IDEBK  |b eng  |e rda  |e pn  |c IDEBK  |d N$T  |d YDX  |d EBLCP  |d NLE  |d OCLCO  |d OPELS  |d N$T  |d OCLCF  |d IDB  |d OCLCQ  |d OTZ  |d OCLCQ  |d U3W  |d MERUC  |d D6H  |d UUM  |d OCLCQ  |d LVT  |d ESU  |d LQU  |d DCT  |d UKMGB  |d OCLCQ  |d S2H  |d HUL  |d OCLCO  |d RBN  |d UAB  |d RRP  |d WYU  |d SFB  |d VT2  |d OCLCO  |d OCL  |d OCLCQ  |d OCLCO 
015 |a GBB6F9095  |2 bnb 
016 7 |a 101701320  |2 DNLM 
016 7 |a 018105033  |2 Uk 
019 |a 962303009  |a 962326190  |a 965129426  |a 968189244  |a 1066624032  |a 1105174688  |a 1105570996  |a 1235845492 
020 |a 0128009926  |q (electronic bk.) 
020 |a 9780128009925  |q (electronic bk.) 
020 |z 0128008717 
020 |z 9780128008713 
035 |a (OCoLC)962412307  |z (OCoLC)962303009  |z (OCoLC)962326190  |z (OCoLC)965129426  |z (OCoLC)968189244  |z (OCoLC)1066624032  |z (OCoLC)1105174688  |z (OCoLC)1105570996  |z (OCoLC)1235845492 
050 4 |a QD96.M3  |b M37 2017 
060 4 |a 2017 B-533 
060 4 |a QY 90 
072 7 |a SCI  |x 013010  |2 bisacsh 
082 0 4 |a 543.65  |2 23 
245 0 0 |a Mass spectrometry for the clinical laboratory. 
264 1 |a [Amsterdam] :  |b Elsevier Ltd. :  |b Academic Press,  |c [2017] 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
505 0 |a Cover ; Title page; Copyright page; Contents; List of Contributors; Preface; Chapter 1 -- Mass spectrometry in the clinical laboratory: determining the need and avoiding pitfalls; 1 -- Clinical mass spectrometry; 1.1 -- Basic mass spectrometry concepts; 1.2 -- Common ion sources for clinical mass spectrometry; 1.2.1 -- Electrospray Ionization (ESI); 1.2.2 -- Atmospheric Pressure Chemical Ionization (APCI); 1.2.3 -- Atmospheric Pressure Photoionization (APPI); 1.3 -- Commonly used mass analyzers; 1.3.1 -- Quadrupole Mass Analyzers; 1.3.2 -- Time-of-Flight Mass Analyzers; 1.3.3 -- Ion Trap Mass Analyzers. 
505 8 |a 1.3.4 -- Hybrid Tandem Mass Analyzers1.4 -- Determining the need for clinical LC-MS; 1.5 -- Potential pitfalls and addressing the challenges; 1.5.1 -- External Quality Assessment and Quality Control; 1.5.2 -- Matrix Effects and Interferences; 1.5.3 -- Technical Hurdles; 1.5.4 -- Practical Considerations; References; Chapter 2 -- Application specific implementation of mass spectrometry platform in clinical laboratories; 1 -- Mass spectrometry versus automated immunoassay platforms; 2 -- Early decisions in the implementation of mass spectrometry in the laboratory. 
505 8 |a 3 -- Importance of internal standards in mass spectrometry4 -- Matrix effects, extraction efficiency, and ion suppression/enhancement; 5 -- Analyte extraction; 6 -- Choice of separation technique: GC versus LC; 7 -- Choice of stationary phase; 8 -- Choice of ionization techniques; 9 -- Choice of mass analyzer; 10 -- Summary; References; Chapter 3 -- Sample preparation techniques for mass spectrometry in the clinical laboratory; 1 -- Why is sample preparation needed for LC-MS/MS?; 2 -- Selecting a sample preparation protocol; 3 -- Description of commonly used clinical sample preparation protocols. 
505 8 |a 3.1 -- Simple-dilution sample preparation protocol (DIL)3.2 -- Simple-protein precipitation sample preparation protocol (PPT); 3.3 -- More complex-liquid-liquid extraction sample preparation protocol (LLE); 3.4 -- Commercial media-phospholipid removal sample preparation protocol (PLR); 3.5 -- Commercial media-supported liquid extraction sample preparation protocol (SLE or SALL); 3.6 -- Commercial media-solid phase extraction sample preparation protocol (SPE); 3.7 -- Online SPE; 4 -- Evaluation of sample preparation protocols; 4.1 -- Evaluating chromatography. 
505 8 |a 4.2 -- Evaluating signal to noise (S/N) at the LLOQ4.3 -- Evaluating matrix effect (ME); 4.3.1 -- Quantitative Matrix Effect Experiment; 4.3.2 -- Qualitative Postcolumn Matrix Effect Experiment; 4.3.3 -- Phospholipid Direct Detection Experiment; 4.3.4 -- Matrix Mixing Experiment; 4.4 -- Evaluating method performance; 4.5 -- Evaluating practicality; 4.6 -- Evaluating robustness; 5 -- Comparison of sample preparation protocols; 6 -- Optimization of sample preparation protocols; 6.1 -- Generic-optimizing for 96-well format; 6.2 -- Generic-optimizing LC injection solvent composition. 
505 8 |a 6.2.1 -- Analyte Solubility. 
504 |a Includes bibliographical references and index. 
520 |a Mass Spectrometry for the Clinical Laboratory is an accessible guide to mass spectrometry and the development, validation, and implementation of the most common assays seen in clinical labs. It provides readers with practical examples for assay development, and experimental design for validation to meet CLIA requirements, appropriate interference testing, measuring, validation of ion suppression/matrix effects, and quality control. These tools offer guidance on what type of instrumentation is optimal for each assay, what options are available, and the pros and cons of each. Readers will find a full set of tools that are either directly related to the assay they want to adopt or for an analogous assay they could use as an example. Written by expert users of the most common assays found in a clinical laboratory (clinical chemists, toxicologists, and clinical pathologists practicing mass spectrometry), the book lays out how experts in the field have chosen their mass spectrometers, purchased, installed, validated, and brought them on line for routine testing. The early chapters of the book covers what the practitioners have learned from years of experience, the challenges they have faced, and their recommendations on how to build and validate assays to avoid problems. These chapters also include recommendations for maintaining continuity of quality in testing. The later parts of the book focuses on specific types of assays (therapeutic drugs, Vitamin D, hormones, etc.). Each chapter in this section has been written by an expert practitioner of an assay that is currently running in his or her clinical lab. 
650 0 |a Mass spectrometry. 
650 0 |a Diagnosis, Laboratory. 
650 0 |a Medical laboratory technology. 
650 1 2 |a Mass Spectrometry  |0 (DNLM)D013058 
650 2 2 |a Clinical Laboratory Techniques  |0 (DNLM)D019411 
650 6 |a Spectrom�etrie de masse.  |0 (CaQQLa)201-0047036 
650 6 |a Diagnostics biologiques.  |0 (CaQQLa)201-0014951 
650 6 |a M�edecine  |x Laboratoires  |x Technique.  |0 (CaQQLa)201-0029482 
650 7 |a mass spectrometry.  |2 aat  |0 (CStmoGRI)aat300225881 
650 7 |a SCIENCE  |x Chemistry  |x Analytic.  |2 bisacsh 
650 7 |a Medical laboratory technology  |2 fast  |0 (OCoLC)fst01014300 
650 7 |a Diagnosis, Laboratory  |2 fast  |0 (OCoLC)fst00892307 
650 7 |a Mass spectrometry  |2 fast  |0 (OCoLC)fst01011435 
700 1 |a Nair, Hari. 
700 1 |a Clarke, William,  |d 1970- 
776 0 8 |i Print version:  |t Mass spectrometry for the clinical laboratory.  |d [Place of publication not identified] : Elsevier Ltd. : Academic Press, 2016  |z 9780128008713  |z 0128008717  |w (OCoLC)953708133 
856 4 0 |u https://sciencedirect.uam.elogim.com/science/book/9780128008713  |z Texto completo