Cargando…

2015 International Building Code Illustrated Handbook: Application Example 307-1 Maximum Allowable Quantity per Control Area /

This video illustrates Application Example 307-1, in which the maximum allowable quantity (MAQ) of hazardous chemicals that can be stored in a Group F-1 occupancy is determined. When the MAQ is exceeded, the occupancy classification of buildings is no longer the most applicable occupancy classifica...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor principal: Klein, Andrew
Formato: Electrónico Video
Idioma:Inglés
Publicado: New York, N.Y. : McGraw-Hill Education LLC., c2015.
Colección:McGraw-Hill's AccessEngineering.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000ngm a22000001i 4500
001 MGH_AE4810703455001
003 IN-ChSCO
005 20160411113829.0
006 m|o|c|||||||||||||
007 cr|una---unuuu
007 vz|uzazuu
008 160411s2015||||nyu|||||o|||||||||v|eng|d
028 4 2 |a 4810703455001  |b McGraw-Hill Education LLC 
040 |a IN-ChSCO  |b eng  |e rda 
041 0 |a eng 
046 |k 2015 
050 4 |a TA368 
082 0 4 |a 620/.002/1   |2 23 
100 1 |a Klein, Andrew,   |u Fire Protection Engineer, A S Klein Engineering, PLLC. 
245 1 4 |a 2015 International Building Code Illustrated Handbook: Application Example 307-1 Maximum Allowable Quantity per Control Area /   |c Andrew Klein. 
264 1 |a New York, N.Y. :   |b McGraw-Hill Education LLC.,   |c c2015. 
300 |a 1 online resource (1 video file, approximately 3 min. 53 sec.):   |b digital, .flv file, sound 
336 |a two-dimensional moving image  |b tdi  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |3 internet archive  |a online resource  |b cr  |2 rdacarrier 
344 |a digital 
347 |a video file  |b MPEG-4  |b Flash 
490 1 |a McGraw-Hill's AccessEngineering 
500 |a Title from title frames. 
518 |a Originally produced by Andrew Klein in 2015. 
520 |a This video illustrates Application Example 307-1, in which the maximum allowable quantity (MAQ) of hazardous chemicals that can be stored in a Group F-1 occupancy is determined. When the MAQ is exceeded, the occupancy classification of buildings is no longer the most applicable occupancy classification but becomes Group H, and a number of additional code requirements becomes mandatory. It is therefore prudent to understand the MAQ limits and how control areas can be utilized to increase the permissible quantity of hazardous chemicals while maintaining the most applicable occupancy classification. The requirements are based on the 2015 International Building Code. 
538 |a Mode of access: World Wide Web.   |b System requirements: Adobe Flash Player. 
546 |a In English. 
588 |a Description based on online resource; title from title screen (Internet Archive, viewed April 11, 2016) 
650 0 |a Building   |x Standards. 
650 0 |a Standards, Engineering. 
655 7 |a Internet videos.  |2 lcgft 
655 7 |a Short films.  |2 lcgft 
710 1 |a McGraw-Hill Education LLC.  |e publisher. 
773 0 |t 2015 International Building Code Illustrated Handbook   |d New York, N.Y. : McGraw-Hill Education, 2015  |z 9781259586125 
830 0 |a McGraw-Hill's AccessEngineering. 
856 4 0 |u https://accessengineeringlibrary.uam.elogim.com/browse/2015-international-building-code-illustrated-handbook/c9781259586125ch03lev1sec07#4810703455001  |z Texto completo