Cargando…

Lighting guide 22 : lighting for control rooms /

Control rooms can be complex, having many operators with their often extensive arrangement of screens around them and perhaps large overview screens on walls in front of them. Many rooms operate 24 hours a day, some monitoring and controlling safety-critical operations. For these reasons establishin...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autores Corporativos: Chartered Institution of Building Services Engineers, Society of Light and Lighting
Otros Autores: Ruffles, Paul, Watts, David, Caple, Richard
Formato: Electrónico eBook
Idioma:Inglés
Publicado: [Place of publication not identified] : Chartered Institution of Building Services Engineers, 2022.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 i 4500
001 KNOVEL_on1373991238
003 OCoLC
005 20231027140348.0
006 m o d
007 cr |||||||||||
008 230315s2022 xx ob u000 0 eng d
040 |a SFB  |b eng  |e rda  |c SFB  |d OCLCF  |d MNU  |d OCLCO 
020 |a 1523150122 
020 |a 9781523150120 
029 1 |a AU@  |b 000074211911 
035 |a (OCoLC)1373991238 
050 4 |a TH7703  |b .R844 2022 
082 0 4 |a 621.32  |2 23 
049 |a UAMI 
245 0 0 |a Lighting guide 22 :  |b lighting for control rooms /  |c Paul Ruffles, David Watts, Richard Caple. 
264 1 |a [Place of publication not identified] :  |b Chartered Institution of Building Services Engineers,  |c 2022. 
300 |a 1 online resource (15 pages). 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
520 |a Control rooms can be complex, having many operators with their often extensive arrangement of screens around them and perhaps large overview screens on walls in front of them. Many rooms operate 24 hours a day, some monitoring and controlling safety-critical operations. For these reasons establishing the geometry between operators, their screens, larger remote room displays, and the lighting and any windows is crucial. Designing the lighting, daylight admission, sunlight control and lighting control systems require discussion and cooperation between the lighting designers and others involved in the design of the room. In control rooms monitoring life- or safety-critical operations if the power to the normal lighting fails full or partial standby lighting will normally be needed throughout the room. As this will be supplied from UPS and/or standby generators, early discussion with the electrical designers is vital. These issues need to be decided upon as early as possible in the design process. Once all building, electrical and display screen/user parameters are established the design of the lighting, and possibly daylight control, can be carried out. As well as making sure no bright images are visible to the users on any of their screens, the room lighting needs to provide a constant minimum level to ensure the operators remain alert - this is most important during the night shift where there may be an increased risk of operators becoming sleepy if the room lighting is dim. 
590 |a Knovel  |b ACADEMIC - Civil Engineering & Construction Materials 
590 |a Knovel  |b ACADEMIC - Mechanics & Mechanical Engineering 
650 0 |a Lighting. 
650 0 |a Control rooms  |x Lighting. 
650 6 |a Salles de commande  |x Éclairage. 
650 7 |a Lighting  |2 fast 
700 1 |a Ruffles, Paul. 
700 1 |a Watts, David. 
700 1 |a Caple, Richard. 
710 2 |a Chartered Institution of Building Services Engineers. 
710 2 |a Society of Light and Lighting. 
856 4 0 |u https://appknovel.uam.elogim.com/kn/resources/kpLGLCR00B/toc  |z Texto completo 