LEADER |
00000cam a2200000 i 4500 |
001 |
KNOVEL_on1043671012 |
003 |
OCoLC |
005 |
20231027140348.0 |
006 |
m o d |
007 |
cr cnu|||||||| |
008 |
180709t20182018enka ob 001 0 eng d |
040 |
|
|
|a UAB
|b eng
|e rda
|e pn
|c UAB
|d UAB
|d LGG
|d UIU
|d OCLCF
|d CDN
|d OTZ
|d STF
|d EBLCP
|d OCL
|d U3G
|d YDX
|d CUS
|d MERUC
|d CUV
|d UKAHL
|d KNOVL
|d N$T
|d OCLCQ
|d OCLCO
|d OCLCQ
|d OCLCO
|d OCLCQ
|
019 |
|
|
|a 1057432947
|
020 |
|
|
|a 9781785612558
|q (electronic bk.)
|
020 |
|
|
|a 1785612557
|q (electronic bk.)
|
020 |
|
|
|a 9781523121045
|q (electronic bk.)
|
020 |
|
|
|a 1523121041
|q (electronic bk.)
|
020 |
|
|
|z 9781785612541
|
020 |
|
|
|z 1785612549
|
035 |
|
|
|a (OCoLC)1043671012
|z (OCoLC)1057432947
|
050 |
|
4 |
|a TK2551
|b .P67 2018eb
|
072 |
|
7 |
|a B0100
|2 inspec
|
072 |
|
7 |
|a B2810D
|2 inspec
|
072 |
|
7 |
|a B2830
|2 inspec
|
072 |
|
7 |
|a B8350
|2 inspec
|
082 |
0 |
4 |
|a 621.314
|
049 |
|
|
|a UAMI
|
245 |
0 |
0 |
|a Power transformer condition monitoring and diagnosis /
|c edited by Ahmed Abu-Siada.
|
264 |
|
1 |
|a London :
|b Institution of Engineering and Technology,
|c 2018.
|
264 |
|
4 |
|c ©2018
|
300 |
|
|
|a 1 online resource (xix, 304 pages) :
|b illustrations
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
490 |
1 |
|
|a IET Energy Engineering ;
|v 104
|
588 |
0 |
|
|a Print version record.
|
504 |
|
|
|a Includes bibliographical references and index.
|
520 |
|
|
|a The following topics are dealt with: power transformer; condition monitoring; dissolved gas analysis; partial discharges; moisture analysis; paper; thermal ageing and mechanical oscillations.
|
505 |
0 |
|
|a Intro; Contents; About the editor; Preface; List of acronyms; 1. Dissolved gas analysis, measurements and interpretations -- Carlos Gamez; 1.1 Introduction; 1.2 Insulating liquids; 1.2.1 Mineral oil; 1.3 The transformer as a chemical reactor; 1.3.1 Gas production mechanisms; 1.4 Oil analysis; 1.4.1 Gas chromatography; 1.5 Oil sampling; 1.5.1 Bottle sampling; 1.5.2 Syringe sampling; 1.6 Interpretation techniques; 1.6.1 Fault types; 1.6.2 Techniques that rely on the gas profile; 1.6.3 Techniques that rely on ratios; 1.6.4 Techniques that rely on rates of change; 1.6.5 Putting it all together
|
505 |
8 |
|
|a 1.7 Future of oil analysis1.7.1 Online monitors; 1.7.2 Larger datasets; 1.7.3 Analysis automation; References; 2. Partial discharges: keys for condition monitoring and diagnosis of power transformers -- Ricardo Albarracıń, Guillermo Robles, Jorge Alfredo Ardila-Rey, Andrea Cavallini and Renzo Passaglia; Abstract; 2.1 Introduction; 2.2 Dielectric materials used in power transformers; 2.3 Effects of ageing in insulation systems of power transformers; 2.3.1 Thermal stress; 2.3.2 Mechanical stress; 2.3.3 Electrical stress; 2.3.4 Ambient stress
|
505 |
8 |
|
|a 2.4 Condition monitoring techniques in power transformers2.4.1 Electrical measurements; 2.4.2 Apparent charge estimation: quasi-integration and calibration; 2.4.3 PD detection in transformers; 2.4.4 Unconventional methods of partial discharge measurements in power transformers; 2.4.5 Methods of partial discharge analysis; 2.5 Conclusions; Acknowledgements; References; 3. Moisture analysis for power transformers -- Beleń Garcıá, Alexander Ceśpedes and Diego Garcıá; 3.1 Introduction; 3.2 Moisture in transformer insulation
|
505 |
8 |
|
|a 3.2.1 Risks associated to the presence of high levels of moisture in transformers3.2.2 Sources of moisture contamination in transformers; 3.3 Moisture dynamics in transformers; 3.3.1 Adsorption and desorption of moisture in cellulosic insulation; 3.3.2 Moisture distribution within transformer solid insulation; 3.3.3 Solubility of water in oil; 3.3.4 Moisture equilibrium between paper and oil; 3.3.5 Moisture equilibrium in alternative fluids; 3.3.6 Moisture dynamics in a transformer under operation; 3.4 Monitoring of moisture content in oil; 3.4.1 Periodical sampling of oil
|
505 |
8 |
|
|a 3.4.2 On-line measure of oil moisture with capacitive sensors3.4.3 Interpretation of the moisture content of oil; 3.5 Estimation of the moisture content of solid insulation from moisture in oil measures; 3.5.1 Determination of moisture content of paper using the equilibrium charts; 3.5.2 Improved methodologies to estimate the moisture content of paper from the measures of moisture content of oil; 3.6 Dielectric response methods for the estimation of moisture in solid insulation; 3.6.1 Theoretical principles; 3.6.2 Frequency dielectric spectroscopy; 3.6.3 Recovery voltage method
|
590 |
|
|
|a Knovel
|b ACADEMIC - Electrical & Power Engineering
|
630 |
0 |
7 |
|a Monitoring.
|2 fast
|0 (OCoLC)fst01787507
|
650 |
|
0 |
|a Electric transformers
|x Testing.
|
650 |
|
0 |
|a Electric discharges.
|
650 |
|
6 |
|a Décharges électriques.
|
650 |
|
7 |
|a Electric transformers
|x Testing.
|2 fast
|0 (OCoLC)fst00905964
|
650 |
|
7 |
|a Electric discharges.
|2 fast
|0 (OCoLC)fst00904680
|
650 |
|
7 |
|a ageing.
|2 inspect
|
650 |
|
7 |
|a chemical analysis.
|2 inspect
|
650 |
|
7 |
|a condition monitoring.
|2 inspect
|
650 |
|
7 |
|a oscillations.
|2 inspect
|
650 |
|
7 |
|a paper.
|2 inspect
|
650 |
|
7 |
|a partial discharges.
|2 inspect
|
650 |
|
7 |
|a power transformer insulation.
|2 inspect
|
700 |
1 |
|
|a Abu-Siada, Ahmed,
|e editor.
|
776 |
0 |
8 |
|i Print version:
|t Power transformer condition monitoring and diagnosis.
|d London : Institution of Engineering and Technology, 2018
|z 9781785612541
|w (OCoLC)1045058025
|
830 |
|
0 |
|a IET energy engineering series ;
|v 104.
|
856 |
4 |
0 |
|u https://appknovel.uam.elogim.com/kn/resources/kpPTCMD00B/toc
|z Texto completo
|
938 |
|
|
|a Askews and Holts Library Services
|b ASKH
|n AH32766469
|
938 |
|
|
|a ProQuest Ebook Central
|b EBLB
|n EBL5639396
|
938 |
|
|
|a EBSCOhost
|b EBSC
|n 1991363
|
938 |
|
|
|a YBP Library Services
|b YANK
|n 15966050
|
994 |
|
|
|a 92
|b IZTAP
|