|
|
|
|
LEADER |
00000cam a2200000 i 4500 |
001 |
KNOVEL_ocn890640728 |
003 |
OCoLC |
005 |
20231027140348.0 |
006 |
m o d |
007 |
cr cnu---unuuu |
008 |
140916s2005 enka ob 001 0 eng d |
040 |
|
|
|a KNOVL
|b eng
|e rda
|e pn
|c KNOVL
|d ZCU
|d OCLCQ
|d VT2
|d UAB
|d REB
|d OCLCQ
|d CEF
|d RRP
|d DKU
|d WYU
|d YOU
|d UKBTH
|d OCLCQ
|d UX1
|d OCLCQ
|d OCLCO
|d OCLCQ
|
016 |
7 |
|
|a 013211442
|2 Uk
|
019 |
|
|
|a 961849902
|a 988637545
|a 999474934
|a 1026434442
|a 1065672960
|a 1096687581
|a 1113620615
|a 1151975400
|a 1159657618
|a 1204526583
|a 1373992006
|
020 |
|
|
|a 9781628709537
|q (electronic bk.)
|
020 |
|
|
|a 1628709537
|q (electronic bk.)
|
020 |
|
|
|z 1903287561
|
020 |
|
|
|z 9781903287569
|
029 |
1 |
|
|a GBVCP
|b 856585416
|
035 |
|
|
|a (OCoLC)890640728
|z (OCoLC)961849902
|z (OCoLC)988637545
|z (OCoLC)999474934
|z (OCoLC)1026434442
|z (OCoLC)1065672960
|z (OCoLC)1096687581
|z (OCoLC)1113620615
|z (OCoLC)1151975400
|z (OCoLC)1159657618
|z (OCoLC)1204526583
|z (OCoLC)1373992006
|
050 |
|
4 |
|a TH7674
|b .N28 2005eb
|
082 |
0 |
4 |
|a 697.92
|2 22
|
049 |
|
|
|a UAMI
|
245 |
0 |
0 |
|a Natural ventilation in non-domestic buildings.
|
264 |
|
1 |
|a London :
|b Chartered Institution of Building Services Engineers :
|b Carbon Trust,
|c 2005.
|
300 |
|
|
|a 1 online resource (64 pages) :
|b color illustrations
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
490 |
1 |
|
|a CIBSE applications manual ;
|v AM10
|
504 |
|
|
|a Includes bibliographical references (pages 60-61) and index.
|
588 |
0 |
|
|a Print version record.
|
505 |
0 |
0 |
|g 1.
|t Introduction:
|t General ; Structure of this publication --
|g 2.
|t Developing the design strategy:
|t Satisfying design requirements ; Selecting a natural ventilation concept ; Driving forces for natural ventilation ; Natural ventilation strategies --
|g 3.
|t Ventilation components and system integration:
|t From strategy to specification ; Ventilation opening types ; Internal obstructions ; Background leakage ; Window stays and automatic actuators ; Control system ; Installation and commissioning --
|g 4.
|t Design calculations:
|t Establishing the required flowrates ; Selecting a ventilation design tool ; Design procedures using envelope flow models ; Input data requirements and selection ; Reservoir effect.
|
520 |
|
|
|a This publication is a major revision of the Applications Manual (AM) first published in 1997. At that time, there was a significant expansion of interest in the application of engineered natural ventilation to the design of non-domestic buildings. The original AM10 sought to capture the state of knowledge as it existed in the mid-90s and present it in a form suited to the needs of every member of the design team. Some 10 years on from the time when the initial manual was conceived, the state of knowledge has increased, and experience in the design and operation of naturally ventilated buildings has grown. This revision of AM10 is therefore a timely opportunity to update and enhance the guidance offered to designers and users of naturally ventilated buildings. --
|c Provided by publisher.
|
590 |
|
|
|a Knovel
|b ACADEMIC - Civil Engineering & Construction Materials
|
590 |
|
|
|a Knovel
|b ACADEMIC - Mechanics & Mechanical Engineering
|
650 |
|
0 |
|a Natural ventilation.
|
650 |
|
6 |
|a Ventilation naturelle.
|
650 |
|
7 |
|a Natural ventilation.
|2 fast
|0 (OCoLC)fst01737456
|
710 |
2 |
|
|a Chartered Institution of Building Services Engineers.
|
776 |
0 |
8 |
|i Print version:
|t Natural ventilation in non-domestic buildings
|z 1903287561
|w (OCoLC)61693789
|
830 |
|
0 |
|a Applications manual (Chartered Institution of Building Services Engineers) ;
|v 10.
|
856 |
4 |
0 |
|u https://appknovel.uam.elogim.com/kn/resources/kpNVNDBCIA/toc
|z Texto completo
|
994 |
|
|
|a 92
|b IZTAP
|