Cargando…

AIChE equipment testing procedure. a guide to performance evaluation / Trayed & packed columns :

"Provides a cost-effective and reliable reference for improving the performance of new and existing process equipment Step-by-step procedures are flexible enough to be applied in a number of industrial applications "--

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor Corporativo: American Institute of Chemical Engineers. Equipment Testing Procedures Committee
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Hoboken, New Jersey : Wiley-AIChE, 2014.
Edición:Third edition.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 i 4500
001 KNOVEL_ocn869367756
003 OCoLC
005 20231027140348.0
006 m o d
007 cr |||||||||||
008 140127s2014 nju ob 001 0 eng
010 |a  2014003278 
040 |a DLC  |b eng  |e rda  |e pn  |c DLC  |d YDX  |d N$T  |d CUI  |d CUS  |d DG1  |d YDXCP  |d CDX  |d CNSPO  |d E7B  |d COO  |d B24X7  |d OCLCQ  |d COCUF  |d DG1  |d UAB  |d MOR  |d MERER  |d OCLCQ  |d LIP  |d PIFBY  |d STF  |d K6U  |d U3W  |d OCLCQ  |d DEBBG  |d OCLCQ  |d CEF  |d CRU  |d RRP  |d ICG  |d OCLCQ  |d ZCU  |d INT  |d VT2  |d OCLCQ  |d OTZ  |d TKN  |d OCLCQ  |d EBLCP  |d MERUC  |d A7U  |d OCLCQ  |d DKC  |d OCLCQ  |d ERF  |d UWW  |d UKAHL  |d S9I  |d OCLCQ  |d UX1  |d MM9  |d EYM  |d OCLCQ  |d OCLCO  |d OCLCQ 
019 |a 870586901  |a 872703389  |a 961585915  |a 962671299  |a 992834527  |a 1007226237  |a 1100436796  |a 1124525197  |a 1148076737  |a 1151948285 
020 |a 9781118860182  |q (epub) 
020 |a 1118860187  |q (epub) 
020 |a 9781118860540  |q (pdf) 
020 |a 1118860543  |q (pdf) 
020 |a 9781118860373  |q (mobi) 
020 |a 1118860373  |q (mobi) 
020 |a 9781118860250  |q (electronic bk.) 
020 |a 111886025X  |q (electronic bk.) 
020 |a 1118627717  |q (paperback) 
020 |a 9781118627716  |q (paperback) 
020 |a 9781523109937  |q (electronic) 
020 |a 1523109939 
020 |z 9781118627716  |q (paperback) 
029 1 |a AU@  |b 000052441626 
029 1 |a CHNEW  |b 000942757 
029 1 |a CHVBK  |b 48023051X 
029 1 |a DEBBG  |b BV041877680 
029 1 |a DEBBG  |b BV043607427 
029 1 |a NZ1  |b 15495770 
035 |a (OCoLC)869367756  |z (OCoLC)870586901  |z (OCoLC)872703389  |z (OCoLC)961585915  |z (OCoLC)962671299  |z (OCoLC)992834527  |z (OCoLC)1007226237  |z (OCoLC)1100436796  |z (OCoLC)1124525197  |z (OCoLC)1148076737  |z (OCoLC)1151948285 
042 |a pcc 
050 0 0 |a TP159.D9 
072 7 |a TEC  |x 009000  |2 bisacsh 
072 7 |a TEC  |x 035000  |2 bisacsh 
082 0 0 |a 620.1/12  |2 23 
084 |a TEC009010  |2 bisacsh 
049 |a UAMI 
245 0 0 |a AIChE equipment testing procedure.  |p Trayed & packed columns :  |b a guide to performance evaluation /  |c prepared by the Equipment Testing Procedures Committee of the American Institute of Chemical Engineers. 
246 3 0 |a Trayed & packed columns 
246 3 |a Trayed and packed columns 
250 |a Third edition. 
264 1 |a Hoboken, New Jersey :  |b Wiley-AIChE,  |c 2014. 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
500 |a Includes index. 
588 0 |a Print version record and CIP data provided by publisher. 
520 |a "Provides a cost-effective and reliable reference for improving the performance of new and existing process equipment Step-by-step procedures are flexible enough to be applied in a number of industrial applications "--  |c Provided by publisher 
504 |a Includes bibliographical references and index. 
505 2 |a Purpose & scope -- Definition and description of terms -- Test planning -- Methods of measurement and sampling -- Test procedure -- Computation results -- Interpretation of results -- Appendix. 
505 0 |a 100.0 PURPOSE & SCOPE -- 101.0 Purpose -- 102.0 Scope -- 200.0 DEFINITION AND DESCRIPTION OF TERMS -- 201.0 Flow Quantities -- 202.0 Key Components -- 203.0 Mass Transfer Efficiency -- 203.1 Theoretical Trays or Plates or Stages -- 203.2 Overall Column Efficiency -- 203.3 Apparent Murphree Tray Efficiency -- 203.4 Ideal Murphree Tray Efficiency -- 203.5 Murphree Point Efficiency -- 203.6 HETP -- 203.7 HTU -- 203.8 NTU -- 204.0 Operating Lines -- 205.0 Pinch -- 206.0 Maximum Throughput -- 206.1 Maximum Hydraulic Throughput -- 206.2 Maximum Operational Capacity206.3 Maximum Efficient Capacity -- 207.0 Minimum Operating Rate -- 208.0 Operating Section -- 209.0 Hardware -- 209.1 Components of a Trayed Column -- 209.2 Components of a Packed Column -- 300.0 TEST PLANNING -- 301.0 Preliminary Preparation -- 301.1 Safety -- 301.2 Environmental Considerations -- 301.3 Test Objectives -- 301.4 Organizational Resources -- 301.5 Schedule -- 301.6 Review of Historic Operating Data -- 302.0 Column Control and Instrumentation -- 303.0 Peripheral Equipment -- 304.0 Pre-test Calculations -- 304.1 Process Simulation -- 304.2 Dry Run -- 305.0 Types of Tests -- 305.1 Performance Tests305.2 Acceptance Tests -- 306.0 Specific Areas of lnterest -- 306.1 Packing Efficiencies -- 306.2 Tray Efficiencies -- 306.3 Overall Column Efficiency -- 306.4 Capacity Limitations -- 307.0 Energy Consumption -- 308.0 Pressure Drop Restrictions -- 309.0 Data Collection Requirements -- 309.1 Process Operating Data -- 309.2 Gamma Scan Data -- 310.0 Conditions of External Streams -- 310.1 Overall and Component Material Balances -- 310.2 Overall Enthalpy Balances -- 311.0 Internal Temperatures -- 311.1 Heat Balances -- 311.2 Internal Profiles -- 312.0 Internal Samples -- 312.1 Internal Samples for Efficiency Checks -- 312.2 Internal Samples for Overall Performance -- 313.0 Pressure Profiles -- 314.0 Data Requirements-Physical Properties -- 314.1 Test Mixtures -- 314.2 Essential Data -- 315.0 Auxiliary Data -- 316.0 Test Procedure Documentation -- 400.0 METHODS OF MEASUREMENT AND SAMPLING -- 401.0 System Controls and Operating Stability -- 402.0 Measurement of Temperatures -- 402.1 Accuracy -- 402.2 Errors -- 403.0 Measurement of Flow Rates -- 403.1 Orifice Meters -- 403.2 Rotameters -- 403.3 Vortex Flow Meters -- 403.4 Coriolis Flow Meters -- 403.5 Magnetic Flow Meters -- 403.6 Pitot Tube (or Annubar) -- 403.7 Direct Volume or Weight Measurement -- 404.0 Measurement of Column Pressure Drop -- 404.1 Instrument -- 404.2 Pressure Taps -- 404.3 Seal Pots -- 404.4 Leakage Check -- 404.5 Accuracy -- 405.0 Sampling Procedure -- 405.1 General -- 405.2 Selection of Sampling Points -- 405.3 Sample Connections -- 405.4 Containers -- 405.5 Sampling of High Boiling Materials -- 405.6 Sampling of Intermediate Boiling Materials -- 405.7 Sampling of Materials Having Boiling Points Below -50° F ( -46°C) -- 405.8 Leakage Check -- 405.9 Labeling and Handling the Samples -- 500.0 TEST PROCEDURE -- 501.0 Preliminary -- 502.0 Test Procedure for Maximum Hydraulic Throughput -- 502.1 Flood Symptoms -- 502.2 Performing Capacity Tests -- 502.3 Operational Test Technique -- Gamma Scanning -- 503.0 Considerations Affecting Efficiency Test Procedure -- 503.0 Considerations Affecting Efficiency Test Procedure -- 503.1 Rigorous Versus Shortcut Efficiency Tests -- 503.2 Strategy of Efficiency Testing -- 503.3 Early Preparation for Efficiency Tests -- 503.4 Last-minute Preparations for Efficiency Tests -- 503.5 Establishment of Steady State Conditions -- 503.6 The Test Day -- 503.7 Concluding Test -- 600.0 COMPUTATION OF RESULTS -- 601.0 Verification of Test Data and Simulation Models -- 602.0 Material Balance -- 602.1 End Effects -- 603.0 Enthalpy Balance -- 603.1 Overall Balance -- 603.2 Internal Flow Rates -- 604.0 Hydraulic Performance -- 604.1 Trayed Column -- 604.2 Packed Column -- 605.0 Efficiency Performance -- 605.1 Trayed Column -- 605.2 Packed Column -- 700.0 INTERPRETATION OF RESULTS -- 701.0 Sources of Experimental Error -- 701.1 Material and Enthalpy Balances -- 702.0 Effects of Experimental Error -- 703.0 Design versus Performance -- 703.1 Mechanical/Tower Equipment -- 703.2 Process Conditions -- 704.0 Hydraulic Performance -- 704.1 Mechanical/Tower Equipment -- 704.2 Tray -- 704.3 Packing -- 704.4 Process Conditions -- 705.0 Mass Transfer Performance -- 705.1 Mechanical/Tower Equipment -- 705.2 Tray -- 705.3 Packing -- 705.4 Maldistribution -- 705.5 Process -- 706.0 Test Troubleshooting -- 706.1 Analysis Procedure -- 706.2 Sampling -- 706.3 Equilibrium Data -- 706.4 Temperature Measurements -- 706.5 Heat and Material Balances -- 706.6 Fluctuation of Process Conditions -- 706.7 Pressure Drop Measurements -- 706.8 Incorrect Prediction of Pressure Drop -- 706.9 Errors in Assumptions in Modeling Mass Transfer -- 706.10 Multicomponent Systems Deviate from Binary Data -- 706.11 High Purity Separation -- 706.12 Test and Design Conditions -- 800.0 APPENDIX -- 801.0 Notation -- 801.1 Greek Symbols -- 802.0 Sample Calculations -- 802.1 General Analysis of Test Data -- 802.2 Packed Column -- 802.3 Trayed Column -- 803.0 References. 
590 |a Knovel  |b ACADEMIC - Chemistry & Chemical Engineering 
650 0 |a Plate towers  |x Evaluation. 
650 0 |a Plate towers  |x Testing. 
650 6 |a Colonnes à plateaux  |x Évaluation. 
650 7 |a TECHNOLOGY & ENGINEERING  |x Chemical & Biochemical.  |2 bisacsh 
710 2 |a American Institute of Chemical Engineers.  |b Equipment Testing Procedures Committee. 
776 0 8 |i Print version:  |t AIChE equipment testing procedure.  |b Third edition.  |d Hoboken : Wiley-AIChE, 2014  |z 9781118627716  |w (DLC) 2013042725 
856 4 0 |u https://appknovel.uam.elogim.com/kn/resources/kpAICEETP9/toc  |z Texto completo 
938 |a Askews and Holts Library Services  |b ASKH  |n AH26183244 
938 |a Books 24x7  |b B247  |n bke00052647 
938 |a Coutts Information Services  |b COUT  |n 28026687 
938 |a EBL - Ebook Library  |b EBLB  |n EBL1629182 
938 |a ebrary  |b EBRY  |n ebr10837589 
938 |a EBSCOhost  |b EBSC  |n 698081 
938 |a YBP Library Services  |b YANK  |n 12673487 
938 |a YBP Library Services  |b YANK  |n 11337099 
938 |a YBP Library Services  |b YANK  |n 11636545 
994 |a 92  |b IZTAP