Distillation troubleshooting /
THE FIRST BOOK OF ITS KIND ON DISTILLATION TECHNOLOGY. The last half-century of research on distillation has tremendously improved our understanding and design of industrial distillation equipment and systems. High-speed computers have taken over the design, control, and operation of towers. Inventi...
Clasificación: | Libro Electrónico |
---|---|
Autor principal: | |
Formato: | Electrónico eBook |
Idioma: | Inglés |
Publicado: |
Hoboken, N.J. :
AIChE : Wiley-Interscience,
©2006.
|
Temas: | |
Acceso en línea: | Texto completo |
Tabla de Contenidos:
- Distillation Troubleshooting; Contents; Preface; Acknowledgments; How to Use this Book; Abbreviations; 1. Troubleshooting Distillation Simulations; 2. Where Fractionation Goes Wrong; 3. Energy Savings and Thermal Effects; 4. Tower Sizing and Material Selection Affect Performance; 5. Feed Entry Pitfalls in Tray Towers; 6. Packed-Tower Liquid Distributors: Number 6 on the Top 10 Malfunctions; 7. Vapor Maldistribution in Trays and Packings; 8. Tower Base Level and Reboiler Return: Number 2 on the Top 10 Malfunctions; 9. Chimney Tray Malfunctions: Part of Number 7 on the Top 10 Malfunctions.
- 10. Draw-Off Malfunctions (Non-Chimney Tray) Part of Number 7 on the Top 10 Malfunctions11. Tower Assembly Mishaps: Number 5 on the Top 10 Malfunctions; 12. Difficulties During Start-Up, Shutdown, Commissioning, and Abnormal Operation: Number 4 on the Top 10 Malfunctions; 13. Water-Induced Pressure Surges: Part of Number 3 on the Top 10 Malfunctions; 14. Explosions, Fires, and Chemical Releases: Number 10 on the Top 10 Malfunctions; 15. Undesired Reactions in Towers; 16. Foaming; 17. The Tower as a Filter: Part A. Causes of Plugging--Number 1 on the Top 10 Malfunctions.
- 18. The Tower as a Filter: Part B. Location of Plugging--Number 1 on the Top 10 Malfunctions19. Coking: Number 1 on the Top 10 Malfunctions; 20. Leaks; 21. Relief and Failure; 22. Tray, Packing, and Tower Damage: Part of Number 3 on the Top 10 Malfunctions; 23. Reboilers That Did Not Work: Number 9 on the Top 10 Malfunctions; 24. Condensers That Did Not Work; 25. Misleading Measurements: Number 8 on the Top 10 Malfunctions; 26. Control System Assembly Difficulties; 27. Where Do Temperature and Composition Controls Go Wrong?; 28. Misbehaved Pressure, Condenser, Reboiler, and Preheater Controls.
- 29. Miscellaneous Control ProblemsDISTILLATION TROUBLESHOOTING DATABASE OF PUBLISHED CASE HISTORIES; References; Index; About the Author.