|
|
|
|
LEADER |
00000cam a2200000 a 4500 |
001 |
KNOVEL_ocn194113478 |
003 |
OCoLC |
005 |
20231027140348.0 |
006 |
m o d |
007 |
cr cn||||||||| |
008 |
080221s2003 mdua ob 000 0 eng d |
040 |
|
|
|a BUF
|b eng
|e pn
|c BUF
|d KNOVL
|d OCLCQ
|d OCLCO
|d KNOVL
|d ZCU
|d KNOVL
|d COCUF
|d COO
|d OCLCE
|d DKDLA
|d CCO
|d E7B
|d CN5CF
|d KNOVL
|d OCLCQ
|d EBLCP
|d OCLCQ
|d STF
|d OCLCQ
|d OCLCO
|d OCLCA
|d BUF
|d OCLCO
|d MERUC
|d OCLCO
|d BRL
|d CEF
|d OCL
|d AU@
|d OCLCQ
|d OCLCO
|d WYU
|d OCLCA
|d OCLCQ
|d UKBTH
|d UX1
|d UAB
|d OCLCO
|d OCLCA
|d OCLCO
|d OCLCQ
|d HNC
|d OCLCQ
|d OCLCO
|
019 |
|
|
|a 290554486
|a 301376792
|a 468758236
|a 475483178
|a 475661863
|a 568113178
|a 645881230
|a 646752478
|a 755664759
|a 923310124
|a 977637021
|a 1037427726
|a 1044567900
|a 1056420731
|a 1058084309
|a 1060945090
|a 1065829635
|a 1075412477
|a 1113610200
|a 1151930791
|a 1159639734
|a 1229060753
|
020 |
|
|
|a 0929600797
|q (print)
|
020 |
|
|
|a 9780929600796
|q (print)
|
020 |
|
|
|a 9781601194732
|q (electronic book)
|
020 |
|
|
|a 1601194730
|q (electronic book)
|
029 |
1 |
|
|a AU@
|b 000042890500
|
029 |
1 |
|
|a GBVCP
|b 830184457
|
029 |
1 |
|
|a NZ1
|b 11658593
|
029 |
1 |
|
|a NZ1
|b 15595369
|
035 |
|
|
|a (OCoLC)194113478
|z (OCoLC)290554486
|z (OCoLC)301376792
|z (OCoLC)468758236
|z (OCoLC)475483178
|z (OCoLC)475661863
|z (OCoLC)568113178
|z (OCoLC)645881230
|z (OCoLC)646752478
|z (OCoLC)755664759
|z (OCoLC)923310124
|z (OCoLC)977637021
|z (OCoLC)1037427726
|z (OCoLC)1044567900
|z (OCoLC)1056420731
|z (OCoLC)1058084309
|z (OCoLC)1060945090
|z (OCoLC)1065829635
|z (OCoLC)1075412477
|z (OCoLC)1113610200
|z (OCoLC)1151930791
|z (OCoLC)1159639734
|z (OCoLC)1229060753
|
042 |
|
|
|a dlr
|
050 |
|
4 |
|a QP519.9.N8
|b P84 2003eb
|
060 |
|
4 |
|a 2005 C-699
|
060 |
|
4 |
|a WN 110
|b P982 2003
|
082 |
0 |
4 |
|a 363.18/9
|2 22
|
049 |
|
|
|a UAMI
|
245 |
0 |
0 |
|a Pulsed fast neutron analysis system used in security surveillance.
|
264 |
|
1 |
|a Bethesda, Maryland :
|b National Council on Radiation Protection and Measurements,
|c ©2003.
|
300 |
|
|
|a 1 online resource (vii, 56 pages) :
|b illustrations : digital, HTML and PDF files
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
490 |
1 |
|
|a NCRP commentary ;
|v no. 17
|
500 |
|
|
|a "Issued December 22, 2003 Revised August 11, 2004."
|
504 |
|
|
|a Includes bibliographical references (pages 53-54).
|
588 |
0 |
|
|a Print version record.
|
506 |
|
|
|3 Use copy
|f Restrictions unspecified
|2 star
|5 MiAaHDL
|
533 |
|
|
|a Electronic reproduction.
|b [Place of publication not identified] :
|c HathiTrust Digital Library,
|d 2010.
|5 MiAaHDL
|
538 |
|
|
|a Master and use copy. Digital master created according to Benchmark for Faithful Digital Reproductions of Monographs and Serials, Version 1. Digital Library Federation, December 2002.
|u http://purl.oclc.org/DLF/benchrepro0212
|5 MiAaHDL
|
583 |
1 |
|
|a digitized
|c 2010
|h HathiTrust Digital Library
|l committed to preserve
|2 pda
|5 MiAaHDL
|
505 |
0 |
|
|a ""Cover ""; ""Preface""; ""Contents""; ""1. Summary""; ""1.1 The Appropriate Dose Limit for Persons Inadvertently Irradiated by the Pulsed Fast Neutron Analysis System""; ""1.2 Effective Dose""; ""1.3 Neutron Activation in Pharmaceuticals and Medical Devices""; ""1.4 Applicable Radiation Protection Concepts for Workers and Members of the Public""; ""1.5 The “As Low As Reasonably Achievable� Principle and Its Application to the Pulsed Fast Neutron Analysis Facility""; ""1.6 Advice on the System Safety Specifications and the Radiation Safety Plan""
|
505 |
8 |
|
|a 1.7 Potential Effects on Nuclear Weapons in Scanned Cargo1.8 Approach to Determination of Effective Dose for Inadvertently Exposed Individuals -- 1.9 Determination of Effective Dose for Inadvertently Exposed Individuals -- 1.10 Validation Measurements and Uncertainties -- 1.11 Application of the Results -- 1.12 Quality Control of Pulsed Fast Neutron Analysis System Performance -- 2. The Appropriate Dose Limit for Inadvertently Exposed Individuals and Levels of Activation Products in Pharmaceuticals and Medical Devices -- 2.1 Introduction -- 2.2 The Appropriate Dose Limit
|
505 |
8 |
|
|a 2.2.1 Prior NCRP Recommendations2.2.2 Recommendations for the Pulsed Fast Neutron Analysis System -- 2.3 Determination of Effective Dose -- 2.3.1 Dosimetry Approach -- 2.3.2 Effective Dose Formulation -- 2.3.3 Specific Application to Monte Carlo Calculations -- 2.4 Neutron Activation in Pharmaceuticals and Medical Devices -- 2.4.1 Approach to Analysis of Neutron Activation Products -- 2.4.2 Neutron Activation Products for the Pulsed Fast Neutron Analysis System -- 2.4.3 Activation Products in Pharmaceuticals Uniformly Distributed in the Body
|
505 |
8 |
|
|a ""2.4.4 Activation Products in Implanted Medical Devices""""2.5 Conclusions""; ""2.5.1 The Appropriate Dose Limit""; ""2.5.2 Determination of Effective Dose""; ""2.5.3 Neutron Activation in Pharmaceuticals and Medical Devices""; ""3. The “As Low As Reasonably Achievable"" Principle and Related Issues""; ""3.1 Introduction""; ""3.2 Description of a Pulsed Fast Neutron Analysis Facility""; ""3.3 Principles of Radiation Protection""; ""3.3.1 Effects of Concern in Radiation Protection""; ""3.3.2 The Radiation Protection System""; ""3.4 “As Low as Reasonably Achievable� Philosophy""
|
505 |
8 |
|
|a ""3.4.1 Application of “As Low As Reasonably Achievable� to the Pulsed Fast Neutron Analysis Facility""""3.4.2 Radiation Levels at the Inspection Station""; ""3.4.3 Doses from Inadvertent Exposure""; ""3.4.4 Activation Products in Food, Pharmaceuticals, Medical Devices, and Other Cargo""; ""3.4.5 Radiation Levels Outside the Facility""; ""3.5 System Safety Specifications""; ""3.6 Radiation Safety Plan""; ""3.6.1 Radiological Area Classifications""; ""3.6.2 Access Controls""; ""3.6.3 Radiation Detection and Monitoring""; ""3.6.4 Interlocks and Emergency Switches""; ""3.6.5 Shielding""
|
546 |
|
|
|a English.
|
590 |
|
|
|a Knovel
|b ACADEMIC - Safety & Industrial Hygiene
|
650 |
|
0 |
|a Nuclear activation analysis
|x Health aspects.
|
650 |
|
0 |
|a Nuclear activation analysis
|x Safety measures.
|
650 |
|
0 |
|a Electronic security systems
|x Safety measures.
|
650 |
|
0 |
|a Radiation
|x Safety measures.
|
650 |
|
0 |
|a Radiation dosimetry.
|
650 |
1 |
2 |
|a Fast Neutrons
|x adverse effects
|
650 |
|
2 |
|a Radiation Protection
|
650 |
|
2 |
|a Radiometry
|
650 |
2 |
2 |
|a Dose-Response Relationship, Radiation
|
650 |
2 |
2 |
|a Neutron Activation Analysis
|x methods
|
650 |
2 |
2 |
|a Radiation Monitoring
|x standards
|
650 |
|
6 |
|a Analyse par activation
|x Sécurité
|x Mesures.
|
650 |
|
6 |
|a Systèmes électroniques de sécurité
|x Sécurité
|x Mesures.
|
650 |
|
6 |
|a Rayonnement
|x Sécurité
|x Mesures.
|
650 |
|
6 |
|a Dosimétrie.
|
650 |
|
6 |
|a Rayonnement
|x Relations dose-effet.
|
650 |
|
7 |
|a dosimetry.
|2 aat
|
650 |
|
7 |
|a Radiation
|x Safety measures
|2 fast
|
650 |
|
7 |
|a Radiation dosimetry
|2 fast
|
710 |
2 |
|
|a National Council on Radiation Protection and Measurements.
|
776 |
0 |
8 |
|i Print version:
|t Pulsed fast neutron analysis system used in security surveillance.
|d Bethesda, Md. : National Council on Radiation Protection and Measurements, ©2003
|z 0929600797
|w (OCoLC)53325111
|
830 |
|
0 |
|a NCRP commentary ;
|v no. 17.
|
856 |
4 |
0 |
|u https://appknovel.uam.elogim.com/kn/resources/kpPFNASUS8/toc
|z Texto completo
|
938 |
|
|
|a ebrary
|b EBRY
|n ebr10233460
|
994 |
|
|
|a 92
|b IZTAP
|