Measurements and performance characteristics of diagnostic x-ray tubes and generators /
This book describes the theoretical principals including potential modes of failures and equipment performance limitations and provides practical advice for making quality assurance (QA) measurements for clinical X-ray tubes and generators.
Clasificación: | Libro Electrónico |
---|---|
Otros Autores: | , , , |
Formato: | Electrónico eBook |
Idioma: | Inglés |
Publicado: |
Bristol [England] (Temple Circus, Temple Way, Bristol BS1 6HG, UK) :
IOP Publishing,
[2022]
|
Edición: | Third edition. |
Colección: | IOP (Series). Release 22.
IPEM-IOP series in physics and engineering in medicine and biology. IPEM report ; no. 32, pt. i. IOP ebooks. 2022 collection. |
Temas: | |
Acceso en línea: | Texto completo |
MARC
LEADER | 00000nam a2200000 i 4500 | ||
---|---|---|---|
001 | IOP_9780750332194 | ||
003 | IOP | ||
005 | 20230109101458.0 | ||
006 | m eo d | ||
007 | cr cn |||m|||a | ||
008 | 230109s2022 enka fob 000 0 eng d | ||
020 | |a 9780750332194 |q ebook | ||
020 | |a 9780750332187 |q mobi | ||
020 | |z 9780750332170 |q print | ||
020 | |z 9780750332200 |q myPrint | ||
024 | 7 | |a 10.1088/978-0-7503-3219-4 |2 doi | |
035 | |a (CaBNVSL)thg00083528 | ||
035 | |a (OCoLC)1358413651 | ||
040 | |a CaBNVSL |b eng |e rda |c CaBNVSL |d CaBNVSL | ||
050 | 4 | |a RC78.3 |b .M436 2022eb | |
060 | 4 | |a WN 650 |b M484 2022eb | |
072 | 7 | |a PHVD |2 bicssc | |
072 | 7 | |a MED080000 |2 bisacsh | |
082 | 0 | 4 | |a 616.07/570289 |2 23 |
130 | 0 | |a Measurement of the performance characteristics of diagnostic X-ray systems used in medicine. |p X-ray tubes and generators. | |
245 | 1 | 0 | |a Measurements and performance characteristics of diagnostic x-ray tubes and generators / |c edited by Daniel Shaw ; with contributions from Jason Fazakerley, Ian Honey, Debbie Saunders. |
250 | |a Third edition. | ||
264 | 1 | |a Bristol [England] (Temple Circus, Temple Way, Bristol BS1 6HG, UK) : |b IOP Publishing, |c [2022] | |
300 | |a 1 online resource (various pagings) : |b illustrations (some color). | ||
336 | |a text |2 rdacontent | ||
337 | |a electronic |2 isbdmedia | ||
338 | |a online resource |2 rdacarrier | ||
490 | 1 | |a [IOP release $release] | |
490 | 1 | |a IPEM-IOP series in physics and engineering in medicine and biology | |
490 | 1 | |a IPEM report ; |v 32, part I | |
490 | 1 | |a IOP ebooks. [2022 collection] | |
500 | |a "Version: 20221201"--Title page verso. | ||
504 | |a Includes bibliographical references. | ||
505 | 0 | |a Preface to the first edition (1980) -- Preface to second edition (1995) -- Preface to the third edition (2022) -- 1. Introduction -- 1.1. Scope -- 1.2. Evidence based QA paper discussion -- 1.3. Framework for testing | |
505 | 8 | |a 2. X-ray tubes and generators -- 2.1. Generator -- 2.2. X-ray tubes | |
505 | 8 | |a 3. Requirements for measuring equipment -- 3.1. Requirements -- 3.2. Summary | |
505 | 8 | |a 4. Equipment inventory and service records -- 5. Safety features -- 5.1. Electrical and mechanical safety -- 5.2. Marking of controls -- 5.3. Prevention against unauthorised/accidental use -- 5.4. Emergency controls -- 5.5. Exposure control -- 5.6. Warning indicators -- 5.7. Indicators and spacers -- 5.8. Interlocks -- 5.9. Observation arrangements -- 5.10. Summary | |
505 | 8 | |a 6. Collimation alignment and scales -- 6.1. Light beam diaphragm -- 6.2. X-ray beam centering -- 6.3. X-ray tube-to-detector alignment -- 6.4. Distance and scales -- 6.5. Collimator attenuation -- 6.6. Summary | |
505 | 8 | |a 7. Tube output and consistency -- 7.1. Repeatability and reproducibility with exposure time and tube (filament) current -- 7.2. Inspection -- 7.3. Summary | |
505 | 8 | |a 8. Exposure time -- 8.1. Inspection -- 8.2. Summary | |
505 | 8 | |a 9. Beam quality -- 9.1. Peak photon energy -- 9.2. Inspection -- 9.3. Summary -- 9.4. Half value layer and filtration -- 9.5. Inspection -- 9.6. Summary | |
505 | 8 | |a 10. Focal spot -- 10.1. Inspection | |
505 | 8 | |a 11. Dose area product assessment -- 11.1. Inspection -- 11.2. Summary | |
505 | 8 | |a 12. Focal plane tomography -- 12.1. Inspection -- 12.2. Summary | |
505 | 8 | |a 13. Anti-scatter grids -- 13.1. Inspection. | |
520 | 3 | |a This book describes the theoretical principals including potential modes of failures and equipment performance limitations and provides practical advice for making quality assurance (QA) measurements for clinical X-ray tubes and generators. | |
521 | |a Physicists and technologists. | ||
530 | |a Also available in print. | ||
538 | |a Mode of access: World Wide Web. | ||
538 | |a System requirements: Adobe Acrobat Reader, EPUB reader, or Kindle reader. | ||
545 | |a Daniel Shaw (Chair) has over 18 years' experience working in medical physics departments around the UK and is an experienced radiation protection advisor and medical physics expert for diagnostic and interventional radiology physics. | ||
588 | 0 | |a Title from PDF title page (viewed on January 9, 2023). | |
650 | 0 | |a Radiography, Medical |x Safety measures. | |
650 | 0 | |a X-rays |x Equipment and supplies |x Safety measures. | |
650 | 0 | |a X-ray tubes |x Measurement. | |
650 | 1 | 2 | |a Radiography. |
650 | 1 | 2 | |a Radiography |x instrumentation. |
650 | 1 | 2 | |a Equipment Safety. |
650 | 1 | 2 | |a X-Rays. |
650 | 7 | |a Medical physics. |2 bicssc | |
650 | 7 | |a MEDICAL / Radiology, Radiotherapy & Nuclear Medicine. |2 bisacsh | |
700 | 1 | |a Shaw, Daniel |c (Researcher in clinical and radiation physics), |e editor. | |
700 | 1 | |a Fazakerley, Jason, |e editor. | |
700 | 1 | |a Honey, Ian, |e editor. | |
700 | 1 | |a Saunders, Debbie |c (Radiation protection expert), |e editor. | |
710 | 2 | |a Institute of Physics (Great Britain), |e publisher. | |
776 | 0 | 8 | |i Print version: |z 9780750332170 |z 9780750332200 |
830 | 0 | |a IOP (Series). |p Release 22. | |
830 | 0 | |a IPEM-IOP series in physics and engineering in medicine and biology. | |
830 | 0 | |a IPEM report ; |v no. 32, pt. i. | |
830 | 0 | |a IOP ebooks. |p 2022 collection. | |
856 | 4 | 0 | |u https://iopscience.uam.elogim.com/book/edit/978-0-7503-3219-4 |z Texto completo |