Air-puff tonometers : challenges and insights /
This book presents the latest achievements and research works of intraocular pressure measurement by the air-puff method presented by experts in the field. It is about tonometers, in particular using the air-puff method. These methods are used, for example, by the Corvis ST. Owing to the ultra-high-...
Clasificación: | Libro Electrónico |
---|---|
Otros Autores: | |
Formato: | Electrónico eBook |
Idioma: | Inglés |
Publicado: |
Bristol [England] (Temple Circus, Temple Way, Bristol BS1 6HG, UK) :
IOP Publishing,
[2019]
|
Colección: | IOP (Series). Release 6.
IOP expanding physics. IOP series in medical and biological image analysis. |
Temas: | |
Acceso en línea: | Texto completo |
MARC
LEADER | 00000nam a2200000 4500 | ||
---|---|---|---|
001 | IOP_9780750320184 | ||
003 | IOP | ||
005 | 20190509172107.0 | ||
006 | m eo d | ||
007 | cr cn |||m|||a | ||
008 | 190506s2019 enka ob 000 0 eng d | ||
020 | |a 9780750320184 |q ebook | ||
020 | |a 9780750320177 |q mobi | ||
020 | |z 9780750320160 |q print | ||
024 | 7 | |a 10.1088/2053-2563/aafee5 |2 doi | |
035 | |a (CaBNVSL)thg00978850 | ||
035 | |a (OCoLC)1100643439 | ||
040 | |a CaBNVSL |b eng |e rda |c CaBNVSL |d CaBNVSL | ||
050 | 4 | |a RE79.T6 |b A477 2019eb | |
060 | 4 | |a WW 220 |b AI298 2019eb | |
072 | 7 | |a MQW |2 bicssc | |
072 | 7 | |a TEC059000 |2 bisacsh | |
082 | 0 | 4 | |a 617.7/41 |2 23 |
245 | 0 | 0 | |a Air-puff tonometers : |b challenges and insights / |c [edited by] Robert Koprowski. |
264 | 1 | |a Bristol [England] (Temple Circus, Temple Way, Bristol BS1 6HG, UK) : |b IOP Publishing, |c [2019] | |
300 | |a 1 online resource (various pagings) : |b illustrations (some color). | ||
336 | |a text |2 rdacontent | ||
337 | |a electronic |2 isbdmedia | ||
338 | |a online resource |2 rdacarrier | ||
490 | 1 | |a [IOP release 6] | |
490 | 1 | |a IOP expanding physics, |x 2053-2563 | |
490 | 1 | |a IOP series in medical and biological image analysis | |
500 | |a "Version: 20190401"--Title page verso. | ||
504 | |a Includes bibliographical references. | ||
505 | 0 | |a 1. Corvis ST tonometer and the possibility of analysing corneal deformation dynamics during intraocular pressure measurement -- 1.1. Introduction -- 1.2. Basics of measurements with the Corvis ST tonometer -- 1.3. Available parameters -- 1.4. Characteristics of dynamic corneal response parameters -- 1.5. Biomechanical-compensated IOP (bIOP) and dynamic corneal response parameters in the available literature -- 1.6. Image processing for obtaining new biomechanical parameters of the cornea -- 1.7. Modelling of dynamic corneal deformation -- 1.8. Summary | |
505 | 8 | |a 2. Air-puff devices, not just tonometry -- 2.1. Introduction -- 2.2. How the instruments work -- 2.3. Accuracy and repeatability -- 2.4. Corneal deformation in healthy corneas -- 2.5. Corneal deformation in diseased corneas -- 2.6. Corneal deformation after surgery -- 2.7. Studies regarding software improvements -- 2.8. Conclusions | |
505 | 8 | |a 3. Clinical applications of the Corvis ST for glaucoma -- 3.1. Introduction -- 3.2. Basic description of the Corvis ST -- 3.3. bIOP : concept and first clinical results -- 3.4. Conclusion | |
505 | 8 | |a 4. Evaluation of the algorithms utilised to diagnose keratoconus for the Corvis ST -- 4.1. Introduction -- 4.2. Methods -- 4.3. Results -- 4.4. Discussion | |
505 | 8 | |a 5. Intraocular pressure and three-dimensional corneal biomechanics -- 5.1. Behind the need for change in glaucoma diagnosis : IOP and corneal biomechanics -- 5.2. Patient-specific geometry : three-dimensional corneal shape -- 5.3. Corneal biomechanics : traditional ex vivo mechanical testing -- 5.4. Corneal biomechanics and IOP : linking non-invasive imaging and simulations -- 5.5. Novel concepts to decipher corneal biomechanics in 3D and IOP -- 5.6. Looking for new alternatives in IOP measurements | |
505 | 8 | |a 6. Ultra-high-speed Scheimpflug imaging for intraocular pressure measurements -- 6.1. IOP measurements with the Corvis ST -- 6.2. Assessment of corneal biomechanical properties with the Corvis ST -- 6.3. Biomechanical corrected IOP (bIOP) -- 6.4. Simulation-based versus empirically-derived correction formulas -- 6.5. Accuracy of bIOP in patients after refractive surgery -- 6.6. bIOP measurements in patients with keratoconus -- 6.7. Ongoing Corvis ST studies in glaucoma -- 6.8. Summary. | |
520 | 3 | |a This book presents the latest achievements and research works of intraocular pressure measurement by the air-puff method presented by experts in the field. It is about tonometers, in particular using the air-puff method. These methods are used, for example, by the Corvis ST. Owing to the ultra-high-speed Scheimpflug camera, which records corneal deformation being the response to an air-puff. In this connection, this book is interdisciplinary in: new methods of image analysis and processing; new engineering methods used in devices; method reducing measurement (intraocular pressure) errors; the change in the blood pulsation phase during measurement affects the results in different ways; other IOP measurement methods (using the air-puff method); medical and engineering problems in air-puff method. This book is recommended reading for those involved in the analysis and processing of images and wanting to expand their knowledge of contemporary diagnostic methods and modern methods of image analysis. Part of IOP Series in Medical and Biological Image Analysis | |
521 | |a Engineers and researchers dealing with image analysis and processing methods and doctors who wish to expand their knowledge of modern diagnostic methods with air-puff methods; students of medical diagnostics. | ||
530 | |a Also available in print. | ||
538 | |a Mode of access: World Wide Web. | ||
538 | |a System requirements: Adobe Acrobat Reader, EPUB reader, or Kindle reader. | ||
545 | |a Professor Robert Koprowski gained his PhD in 2003, Habilitation in 2015 and Professor in 2018. He is currently based at the Institute of Computer Science and Department of Biomedical Computer Systems at the University of Silesia. For 20 years, he has been working on analysis and processing of biomedical images, with particular emphasis on the full automation of measurement for a large inter-individual variability of patients. | ||
588 | 0 | |a Title from PDF title page (viewed on May 6, 2019). | |
650 | 0 | |a Intraocular pressure |x Measurement. | |
650 | 0 | |a Tonometry. | |
650 | 1 | 2 | |a Intraocular Pressure. |
650 | 1 | 2 | |a Tonometry, Ocular |x instrumentation. |
650 | 7 | |a Biomedical engineering. |2 bicssc | |
650 | 7 | |a TECHNOLOGY & ENGINEERING / Biomedical. |2 bisacsh | |
700 | 1 | |a Koprowski, Robert, |e editor. | |
710 | 2 | |a Institute of Physics (Great Britain), |e publisher. | |
776 | 0 | 8 | |i Print version: |z 9780750320160 |
830 | 0 | |a IOP (Series). |p Release 6. | |
830 | 0 | |a IOP expanding physics. | |
830 | 0 | |a IOP series in medical and biological image analysis. | |
856 | 4 | 0 | |u https://iopscience.uam.elogim.com/book/978-0-7503-2018-4 |z Texto completo |