Cargando…

Flow injection analysis : instrumentation and applications /

The concept of flow injection analysis (FIA) was introduced in the mid-seventies. It was preceded by the success of segmented flow analysis, mainly in clinical and environmental analysis. This advance, as well as the development of continuous monitors for process control and environmental monitors,...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor principal: Trojanowicz, Marek
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Singapore ; River Edge, NJ : World Scientific, ©2000.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 a 4500
001 EBSCO_ocn827944985
003 OCoLC
005 20231017213018.0
006 m o d
007 cr cnu---unuuu
008 130218s2000 si a ob 000 0 eng d
040 |a N$T  |b eng  |e pn  |c N$T  |d IDEBK  |d E7B  |d OCLCF  |d YDXCP  |d EBLCP  |d OCLCQ  |d AGLDB  |d OCLCQ  |d VTS  |d AU@  |d STF  |d M8D  |d OCLCO  |d UKAHL  |d OCLCQ  |d LEAUB  |d AJS  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO 
016 7 |a 000021460898  |2 AU 
019 |a 854973965  |a 1058006443  |a 1086425184 
020 |a 9789812813725  |q (electronic bk.) 
020 |a 9812813721  |q (electronic bk.) 
020 |z 9810227108 
020 |z 9789810227104 
029 1 |a AU@  |b 000058045959 
029 1 |a DEBBG  |b BV043140134 
029 1 |a DEBSZ  |b 421304049 
029 1 |a GBVCP  |b 80427147X 
035 |a (OCoLC)827944985  |z (OCoLC)854973965  |z (OCoLC)1058006443  |z (OCoLC)1086425184 
050 4 |a QD79.I5  |b T76 2000eb 
070 |a QD79.I5  |b T76 2000 
072 0 |a X500 
072 7 |a SCI  |x 013010  |2 bisacsh 
082 0 4 |a 543/.07  |2 22 
084 |a VG 5170  |2 rvk 
049 |a UAMI 
100 1 |a Trojanowicz, Marek. 
245 1 0 |a Flow injection analysis :  |b instrumentation and applications /  |c Marek Trojanowicz. 
260 |a Singapore ;  |a River Edge, NJ :  |b World Scientific,  |c ©2000. 
300 |a 1 online resource (xiii, 481 pages) :  |b illustrations 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
504 |a Includes bibliographical references. 
505 0 0 |t Molecular Spectroscopy Detection --  |t Visible Absorption Spectrophotometry --  |t Detectors --  |t Measuring Procedures --  |t Kinetic Methods of Detection --  |t Determination of Gaseous Analytes --  |t Multicomponent Determinations --  |t FIA or Liquid Chromatography? --  |t Detection in the Ultraviolet Region --  |t Infrared Detection --  |t Turbidimetric Detection --  |t Molecular Luminescence Detection Methods --  |t Fluorimetric Detection --  |t Chemiluminescence Detection --  |t Other Molecular Spectroscopic Detection Methods --  |t Atomic Spectroscopy Detection Methods --  |t Atomic Absorption Spectroscopy --  |t Flow Injection Systems with Flame Atomisation --  |t Electrothermal Atomisation --  |t Measurements Involving Conversion of the Analyte into the Gaseous Phase --  |t Atomic Emission Spectroscopy --  |t Flame Photometry --  |t Emission Spectroscopy Based on Plasma Sources --  |t Atomic Fluorescence Spectroscopy --  |t Electrochemical Detection Methods --  |t Potentiometric Detection --  |t Properties of Potentiometric Detectors in FIA --  |t Construction of Detectors --  |t Measuring Techniques --  |t Amperometric Detection --  |t Principle of Detection --  |t Flow-Through Cells and Electrode Materials --  |t Measuring Procedures --  |t Scanning and Stripping Methods --  |t Voltammetric Detection --  |t Voltammetric Stripping --  |t Potentiometric Stripping --  |t Conductometric Detection --  |t Flow Injection Coulometry --  |t Enzymatic Methods of Detection and Immunoassays --  |t Enzymatic Assays --  |t Systems with Soluble Enzymes --  |t Systems with Immobilised Enzyme Reactors --  |t Biosensors as Detectors in FIA --  |t Multicomponent Enzymatic Assays. 
588 0 |a Print version record. 
520 |a The concept of flow injection analysis (FIA) was introduced in the mid-seventies. It was preceded by the success of segmented flow analysis, mainly in clinical and environmental analysis. This advance, as well as the development of continuous monitors for process control and environmental monitors, ensured the success of the FIA methodology. As an exceptionally effective means of mechanization for various procedures of wet chemical analysis, the FIA methodology, in use with a whole arsenal of detection methods of modern analytical chemistry, proved to be of great interest to many. The fast and. 
590 |a eBooks on EBSCOhost  |b EBSCO eBook Subscription Academic Collection - Worldwide 
650 0 |a Instrumental analysis. 
650 0 |a Flow injection analysis. 
650 6 |a Analyse instrumentale. 
650 6 |a Analyse par injection en écoulement. 
650 7 |a SCIENCE  |x Chemistry  |x Analytic.  |2 bisacsh 
650 7 |a Flow injection analysis  |2 fast 
650 7 |a Instrumental analysis  |2 fast 
650 7 |a Fließinjektionsanalyse  |2 gnd 
650 7 |a Metodos instrumentais de analise (quimica)  |2 larpcal 
776 0 8 |i Print version:  |a Trojanowicz, Marek.  |t Flow injection analysis.  |d Singapore ; River Edge, NJ : World Scientific, ©2000  |z 9810227108  |w (DLC) 00038177  |w (OCoLC)43851474 
856 4 0 |u https://ebsco.uam.elogim.com/login.aspx?direct=true&scope=site&db=nlebk&AN=512618  |z Texto completo 
938 |a Askews and Holts Library Services  |b ASKH  |n AH24685754 
938 |a ProQuest Ebook Central  |b EBLB  |n EBL1223300 
938 |a ebrary  |b EBRY  |n ebr10699284 
938 |a EBSCOhost  |b EBSC  |n 512618 
938 |a ProQuest MyiLibrary Digital eBook Collection  |b IDEB  |n cis25506964 
938 |a YBP Library Services  |b YANK  |n 9966493 
994 |a 92  |b IZTAP