Cargando…

Soft and Stiffness-Controllable Robotics Solutions for Minimally Invasive Surgery : the STIFF-FLOP Approach.

Soft and Stiffness-controllable Robotics Solutions for Minimally Invasive Surgery presents the results of a research project, funded by European Commission, STIFF-FLOP: STIFFness controllable Flexible and Learn-able manipulator for surgical Operations. In Minimally Invasive Surgery (MIS), tools go t...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor principal: Konstantinova, Jelizaveta
Otros Autores: Wurdemann, Helge, Shafti, Ali, Shiva, Ali, Althoefer, Kaspar
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Aalborg : River Publishers, 2018.
Colección:River Publishers series in automation, control and robotics.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 i 4500
001 EBOOKCENTRAL_on1049912698
003 OCoLC
005 20240329122006.0
006 m o d
007 cr |n|---|||||
008 180825s2018 xx o 000 0 eng d
040 |a EBLCP  |b eng  |e pn  |c EBLCP  |d YDX  |d MERUC  |d OCLCQ  |d N$T  |d OCLCF  |d UKAHL  |d OCLCQ  |d K6U  |d OCLCO  |d OCLCQ  |d TYFRS  |d PSYSI  |d OCLCQ  |d OCLCO  |d TMA  |d OCLCQ 
019 |a 1049609331 
020 |a 8793519710 
020 |a 9788793519718  |q (electronic bk.) 
020 |a 9781003339588  |q (electronic bk.) 
020 |a 1003339581  |q (electronic bk.) 
020 |a 9781000799477  |q (electronic bk. : EPUB) 
020 |a 1000799476  |q (electronic bk. : EPUB) 
020 |a 9781000799330  |q (electronic bk. : PDF) 
020 |a 1000799336  |q (electronic bk. : PDF) 
020 |z 8793519729 
020 |z 9788793519725 
024 7 |a 10.1201/9781003339588  |2 doi 
029 1 |a AU@  |b 000065529660 
035 |a (OCoLC)1049912698  |z (OCoLC)1049609331 
037 |a 9781003339588  |b Taylor & Francis 
050 4 |a RD33.53 
072 7 |a MED  |x 085000  |2 bisacsh 
072 7 |a SCI  |x 024000  |2 bisacsh 
072 7 |a TEC  |x 037000  |2 bisacsh 
072 7 |a TJFM1  |2 bicssc 
082 0 4 |a 617.9178 
049 |a UAMI 
100 1 |a Konstantinova, Jelizaveta. 
245 1 0 |a Soft and Stiffness-Controllable Robotics Solutions for Minimally Invasive Surgery :  |b the STIFF-FLOP Approach. 
260 |a Aalborg :  |b River Publishers,  |c 2018. 
300 |a 1 online resource (420 pages) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a River Publishers Series in Automation, Control and Robotics Ser. 
588 0 |a Print version record. 
505 0 |a Front Cover; Half Title Page; RIVER PUBLISHERS SERIES IN AUTOMATION, CONTROL AND ROBOTICS; Tilte Page; Copyright Page; Contents; Preface; Acknowledgements; List of Contributors; List of Figures; List of Tables; List of Abbreviations; PART I -- Development of Silicone-based Stiffness Controllable Actuators; Chapter 1 -- Technology Selection; 1.1 Manipulator Specifications; 1.1.1 Medical Requirements; 1.1.2 Technical Specifications; 1.2 Technological Overview of Different Actuation Strategies; 1.2.1 Active Motion Technology Survey; 1.2.1.1 Electromagnetic motors; 1.2.1.2 Electro active polymers. 
505 8 |a 1.2.1.3 Shape memory alloys1.2.1.4 Shape memory polymers; 1.2.1.5 Flexible fluidic actuator; 1.2.2 Discussion and Choice of Active Motion Technology; 1.2.3 Stiffness Variation Technology Survey; 1.2.4 Comparison and Choice; References; Chapter 2 -- Design of the Multi-module Manipulator; 2.1 The Design of the Single Module; 2.1.1 Active Motion; 2.1.2 Stiffness variation; 2.2 Connection of Multiple Modules; 2.3 Complete Characterization of the 2-Module Manipulator; 2.3.1 Fabrication; 2.3.2 Workspace Evaluation; 2.3.2.1 Methods; 2.3.2.2 Results; 2.3.3 Junction Characterization; 2.3.3.1 Methods. 
505 8 |a 2.3.3.2 Results2.3.4 Stiffness Characterization; 2.3.4.1 Methods; 2.3.4.2 Results; 2.3.5 Combined Force and Stiffening Experiments; 2.3.5.1 Methods; 2.3.5.2 Results; References; Chapter 3 -- Soft Manipulator Actuation Module -- with Reinforced Chambers; 3.1 Introduction; 3.1.1 Change of the Chamber Cross Section Area; 3.1.2 Chamber Cross Section Center Displacement; 3.1.3 Friction between the Silicone Body and Braided Sleeve; 3.1.4 Sensor Interaction; 3.2 Proposed Improvements; 3.2.1 Possible Solutions; 3.2.2 Design; 3.3 Manufacturing; 3.4 Tests; 3.4.1 Pneumatic Actuation. 
505 8 |a 3.4.2 Hydraulic Actuation3.4.3 External Force; 3.5 Stiffening Mechanism; 3.5.1 Basic Module Design; 3.5.2 Optimised Module Design; 3.6 Conclusions; Acknowledgement; References; Chapter 4 -- Antagonistic Actuation Principle for a Silicone-based Soft Manipulator; 4.1 Introduction; 4.2 Background; 4.3 Bio-Inspiration and Contributions; 4.4 Integration of the Antagonistic Stiffening Mechanism; 4.4.1 Embedding Tendon-driven Actuation into a STIFF-FLOP Segment; 4.4.2 Setup of the Antagonistic Actuation Architecture; 4.5 Test Protocol, Experimental Results, and Discussion; 4.5.1 Methodology. 
505 8 |a 4.5.2 Experimental Results4.5.3 Discussion; 4.6 Conclusions; 4.7 Funding; References; Chapter 5 -- Smart Hydrogel for Stiffness Controllable Continuum Manipulators: A Conceptual Design; 5.1 Introduction; 5.2 Materials and Methods; 5.2.1 Active Hydrogel Preparation; 5.2.2 Active Hydrogel Properties and Ion Pattern Printing; 5.3 Experiments and Discussion; 5.3.1 Swelling Test; 5.3.2 Stiffness Test; 5.4 Conclusion and Future Works; References; PART II -- Creation and Integration of Multiple Sensing Modalities; Chapter 6 -- Optical Force and Torque Sensor for Flexible Robotic Manipulators. 
500 |a 6.1 Introduction. 
520 |a Soft and Stiffness-controllable Robotics Solutions for Minimally Invasive Surgery presents the results of a research project, funded by European Commission, STIFF-FLOP: STIFFness controllable Flexible and Learn-able manipulator for surgical Operations. In Minimally Invasive Surgery (MIS), tools go through narrow openings and manipulate soft organs that can move, deform, or change stiffness. There are limitations on modern laparoscopic and robot-assisted surgical systems due to restricted access through Trocar ports, lack of haptic feedback, and difficulties with rigid robot tools operating inside a confined space filled with organs. Also, many control algorithms suffer from stability problems in the presence of unexpected conditions. Yet biological "manipulators", like the octopus arm can manipulate objects while controlling the stiffness of selected body parts and being inherently compliant when interacting with objects. STIFF-FLOP robot is an innovative soft robotic arm that can squeeze through a standard MIS, reconfigure itself and stiffen by hydrostatic actuation to perform compliant force control tasks while facing unexpected situations. Technical topics discussed in the book include:Soft actuatorsContinuum soft manipulatorsControl, kinematics and navigation of continuum manipulatorsOptical sensors for force, torque, and curvatureHaptic feedback and human interface for surgical systemsValidation of soft stiffness controllable robots 
545 0 |a Jelizaveta Konstantinova, Helge Wurdemann, Ali Shafti 
590 |a ProQuest Ebook Central  |b Ebook Central Academic Complete 
650 0 |a Endoscopic surgery  |x Technological innovations. 
650 0 |a Surgical instruments and apparatus  |x Design and construction. 
650 6 |a Chirurgie endoscopique  |x Innovations. 
650 7 |a MEDICAL  |x Surgery  |x General.  |2 bisacsh 
650 7 |a SCIENCE / Energy  |2 bisacsh 
650 7 |a TECHNOLOGY / Robotics  |2 bisacsh 
650 7 |a Endoscopic surgery  |x Technological innovations  |2 fast 
650 7 |a Surgical instruments and apparatus  |x Design and construction  |2 fast 
700 1 |a Wurdemann, Helge. 
700 1 |a Shafti, Ali. 
700 1 |a Shiva, Ali. 
700 1 |a Althoefer, Kaspar. 
776 0 8 |i Print version:  |a Konstantinova, Jelizaveta.  |t Soft and Stiffness-Controllable Robotics Solutions for Minimally Invasive Surgery : The STIFF-FLOP Approach.  |d Aalborg : River Publishers, ©2018  |z 9788793519725 
830 0 |a River Publishers series in automation, control and robotics. 
856 4 0 |u https://ebookcentral.uam.elogim.com/lib/uam-ebooks/detail.action?docID=5493978  |z Texto completo 
936 |a BATCHLOAD 
938 |a Askews and Holts Library Services  |b ASKH  |n AH35016977 
938 |a EBSCOhost  |b EBSC  |n 1874787 
938 |a YBP Library Services  |b YANK  |n 15660928 
994 |a 92  |b IZTAP