Cargando…

Wireless power transfer and data communication for neural implants : case study : epilepsy monitoring /

This book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autores principales: Yılmaz, Gürkan (Autor), Dehollain, Catherine (Autor)
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Cham, Switzerland : Springer, 2017.
Colección:Analog circuits and signal processing series.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000 i 4500
001 EBOOKCENTRAL_ocn967656020
003 OCoLC
005 20240329122006.0
006 m o d
007 cr cnu|||unuuu
008 170104s2017 sz ob 001 0 eng d
040 |a N$T  |b eng  |e rda  |e pn  |c N$T  |d IDEBK  |d GW5XE  |d N$T  |d EBLCP  |d YDX  |d OCLCF  |d NJR  |d CNCGM  |d UPM  |d MERER  |d Z5A  |d OCLCQ  |d VT2  |d UAB  |d IOG  |d U3W  |d CAUOI  |d ICW  |d OCLCQ  |d KSU  |d EZ9  |d AU@  |d OCLCQ  |d ESU  |d OCLCQ  |d LVT  |d WYU  |d UKMGB  |d OCLCQ  |d AUD  |d OCLCQ  |d ERF  |d UKBTH  |d UKAHL  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCL  |d OCLCQ 
016 7 |a 019136227  |2 Uk 
019 |a 967884153  |a 974651102  |a 981776484  |a 1005802485  |a 1011849502  |a 1048135145  |a 1058312551  |a 1066499196  |a 1066691816  |a 1086520152  |a 1112604418  |a 1113134867  |a 1113595758  |a 1127200929 
020 |a 9783319493374  |q (electronic bk.) 
020 |a 331949337X  |q (electronic bk.) 
020 |a 3319493361 
020 |a 9783319493367 
020 |z 9783319493367  |q (print) 
024 7 |a 10.1007/978-3-319-49337-4  |2 doi 
029 1 |a AU@  |b 000061154661 
029 1 |a AU@  |b 000065091419 
029 1 |a GBVCP  |b 878027017 
029 1 |a UKMGB  |b 019136227 
029 1 |a AU@  |b 000067495530 
029 1 |a AU@  |b 000074043927 
035 |a (OCoLC)967656020  |z (OCoLC)967884153  |z (OCoLC)974651102  |z (OCoLC)981776484  |z (OCoLC)1005802485  |z (OCoLC)1011849502  |z (OCoLC)1048135145  |z (OCoLC)1058312551  |z (OCoLC)1066499196  |z (OCoLC)1066691816  |z (OCoLC)1086520152  |z (OCoLC)1112604418  |z (OCoLC)1113134867  |z (OCoLC)1113595758  |z (OCoLC)1127200929 
037 |a com.springer.onix.9783319493374  |b Springer Nature 
050 4 |a TK3091 
072 7 |a TEC  |x 009070  |2 bisacsh 
072 7 |a TJFC  |2 bicssc 
082 0 4 |a 621.319  |2 23 
049 |a UAMI 
100 1 |a Yılmaz, Gürkan,  |e author. 
245 1 0 |a Wireless power transfer and data communication for neural implants :  |b case study : epilepsy monitoring /  |c Gürkan Yılmaz, Catherine Dehollain. 
264 1 |a Cham, Switzerland :  |b Springer,  |c 2017. 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a Analog circuits and signal processing 
504 |a Includes bibliographical references and index. 
588 0 |a Online resource; title from PDF title page (SpringerLink, viewed January 18, 2017). 
505 0 |a Preface; Contents; Acronyms; 1 Introduction; 1.1 Problem Definition; 1.2 Motivation and Research Objectives; 1.2.1 Next Generation Neural Recording Systems; 1.2.2 Research Objectives; 1.3 Neural Data Acquisition; 1.4 Anticipated Challenges; 1.5 Book Outline; References; 2 System Overview; 2.1 System Specifications; 2.2 System-Level Solutions; 2.2.1 Single-Frequency Approach; 2.2.2 Two-Frequency Approach; 2.3 Summary; References; 3 Wireless Power Transfer; 3.1 Implant Powering Solutions; 3.1.1 Ambient Energy Harvesting; 3.1.2 Battery Usage; 3.1.3 Wireless Power Transfer. 
505 8 |a 3.2 Wireless Power Transfer3.3 Magnetic Coupling; 3.4 Implantable Remote Powering Electronics; 3.4.1 Rectifier; 3.4.2 Voltage Regulator; 3.5 Summary; References; 4 Wireless Data Communication; 4.1 Bidirectional Wireless Communication; 4.2 Uplink Communication on the Power Transfer Link; 4.2.1 Modulator; 4.2.2 ASK Demodulator; 4.3 Uplink Communication with a Dedicated Transmitter and Receiver; 4.3.1 Oscillator; 4.3.2 Loop Antenna; 4.3.3 External Base Station Receiver; 4.4 Downlink Communication; 4.5 Clock Recovery; 4.6 Summary; References; 5 Packaging of the Implant; 5.1 Background. 
505 8 |a 5.2 Diffusion Modeling of a Polymeric Package5.3 Temperature Elevation Considerations; 5.4 Summary; References; 6 System-Level Experiments and Results; 6.1 System Integration and Characterization; 6.1.1 Single-Frequency Approach; 6.1.2 Two-Frequency Approach; 6.2 In vitro Experiments; 6.2.1 Long-Term In vitro Experiments; 6.3 In vivo Experiments; 6.3.1 Surgical Procedure for the Implantation of the Electrode Array into a Rat Brain; 6.4 Summary; References; 7 Conclusion; Index. 
520 |a This book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size, power consumption, and data rate. In addition to theoretical background which explains the relevant technical challenges, the authors provide practical, step-by-step solutions to these problems. Readers will gain understanding of the numerical values in such a system, enabling projections for feasibility of new projects. Provides complete, system-level perspective for implantable batteryless biomedical system; Extends design example to implementation and long term in-vitro validation; Discusses system design concerns regarding wireless power transmission and wireless data communication, particularly for systems in which both are performed on the same channel/frequency; Presents fully-integrated, implantable system and hermetically sealed packaging. 
590 |a ProQuest Ebook Central  |b Ebook Central Academic Complete 
650 0 |a Wireless power transmission. 
650 0 |a Wireless communication systems. 
650 0 |a Brain-computer interfaces. 
650 6 |a Transmission d'énergie sans fil. 
650 6 |a Transmission sans fil. 
650 6 |a Interfaces cerveau-ordinateur. 
650 7 |a Biomedical engineering.  |2 bicssc 
650 7 |a Electronics engineering.  |2 bicssc 
650 7 |a Circuits & components.  |2 bicssc 
650 7 |a TECHNOLOGY & ENGINEERING  |x Mechanical.  |2 bisacsh 
650 7 |a Brain-computer interfaces  |2 fast 
650 7 |a Wireless communication systems  |2 fast 
650 7 |a Wireless power transmission  |2 fast 
700 1 |a Dehollain, Catherine,  |e author. 
758 |i has work:  |a Wireless power transfer and data communication for neural implants (Text)  |1 https://id.oclc.org/worldcat/entity/E39PCFQkvQhpPtxWQ7hfx7Fwcq  |4 https://id.oclc.org/worldcat/ontology/hasWork 
776 0 8 |i Print version:  |a Yilmaz, Gürkan.  |t Wireless Power Transfer and Data Communication for Neural Implants : Case Study: Epilepsy Monitoring.  |d Cham : Springer International Publishing, ©2017  |z 9783319493367 
830 0 |a Analog circuits and signal processing series. 
856 4 0 |u https://ebookcentral.uam.elogim.com/lib/uam-ebooks/detail.action?docID=4774781  |z Texto completo 
938 |a Askews and Holts Library Services  |b ASKH  |n AH32382606 
938 |a EBL - Ebook Library  |b EBLB  |n EBL4774781 
938 |a EBSCOhost  |b EBSC  |n 1398463 
938 |a ProQuest MyiLibrary Digital eBook Collection  |b IDEB  |n cis37325193 
938 |a YBP Library Services  |b YANK  |n 13322358 
994 |a 92  |b IZTAP