|
|
|
|
LEADER |
00000cam a22000003i 4500 |
001 |
EBOOKCENTRAL_ocn869809735 |
003 |
OCoLC |
005 |
20240329122006.0 |
006 |
m o d |
007 |
cr cnu|||unuuu |
008 |
140204s2014 xx o 000 0 eng d |
040 |
|
|
|a VALIL
|b eng
|e rda
|e pn
|c VALIL
|d IDEBK
|d TEF
|d OCLCO
|d OCLCF
|d YDXCP
|d EBLCP
|d OCLCQ
|d OCLCO
|d OCLCQ
|d CUY
|d ICG
|d ZCU
|d AU@
|d OCLCQ
|d DKC
|d OCLCQ
|d TEFOD
|d OCLCO
|d OCLCQ
|d OCLCO
|d OCLCL
|
019 |
|
|
|a 907231538
|
020 |
|
|
|a 9781780405063
|q (electronic bk.) (PDF)
|
020 |
|
|
|a 1780405065
|q (electronic bk.) (PDF)
|
029 |
1 |
|
|a AU@
|b 000056892344
|
035 |
|
|
|a (OCoLC)869809735
|z (OCoLC)907231538
|
050 |
|
4 |
|a TD719
|
082 |
0 |
4 |
|a 628.3
|2 23
|
049 |
|
|
|a UAMI
|
100 |
1 |
|
|a Flogel, Jerome.
|
245 |
1 |
0 |
|a Sewer Lateral Electro Scan Field Verification Pilot.
|
264 |
|
1 |
|a [Place of publication not identified] :
|b Iwa Publishing,
|c 2014.
|
300 |
|
|
|a 1 online resource (122 pages)
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
520 |
|
|
|a This research effort evaluated an innovative sewer lateral condition assessment tool in unique testing conditions, providing an opportunity for comparison to other traditional assessment approaches. This study field tested over 100 sanitary sewer lateral pipes for potential infiltration-generating defects using the Electro Scan ES-38TM technology according to ASTM F2550-006. Results of these inspections were compared to the results of other infiltration data produced in rainfall simulation tests of the same laterals and water exfiltration tests of each scanned pipe. The Electro Scan ES-38TM measurements were also compared to closed-circuit television (CCTV) inspection of laterals according to NASSCO Pipeline Assessment Certification Program (PACP) standards. Statistical comparisons of Electro Scan ES-38TM assessments to estimated leakage rates, from a field rainfall simulation test, were performed to determine the best means of correlating the two data sets. The research effort was used to test the Electro Scan approach against the dye water/rainfall simulation testing techniques that the City of Wauwatosa (Wauwatosa) has already used to derive convincing condition information in general and on specific properties within the proposed testing area. Prior to this research effort, Electro Scan technology had only been tested side-by-side against CCTV inspection information. The objectives of this proposed research effort were as follows: Test Electro Scan ES-38TM in the two pilot lateral rehabilitation project areas; 1. Compare Electro Scan ES-38TM results to pre-rehabilitation condition dye water/rainfall simulation tests; 2. Compare Electro Scan ES-38TM results to CCTV inspection results; 3. Perform water exfiltration tests and compare results to Electro Scan ES-38TM results; 4.?Evaluate the feasibility of performing Electro Scan ES-38TM tests from basement cleanouts; and 5. Establish pros and cons of Electro Scan ES-38TM lateral condition evaluations, including estimated costs.
|
505 |
0 |
|
|a Cover; Copyright; Acknowledgments; Abstract and Benefits; Table of Contents; List of Tables; List of Figures; List of Acronyms and Abbreviations; Executive Summary; Chapter 1.0: Report Purpose; Chapter 2.0: Research Objectives/Design; 2.1 Background Information; 2.2 Electro Scan Testing Approach; 2.3 Water Exfiltration Testing Approach; 2.4 Collected Data; Chapter 3.0: Field Testing and Results; 3.1 Process; 3.2 Results; 3.3 Duplicates Evaluation; 3.4 Scans of Laterals That Have Been Rehabilitated or Repaired; 3.5 Water Exfiltration Testing and Results; 3.5.1 Testing Process; 3.5.2 Results.
|
505 |
8 |
|
|a Chapter 4.0: Data Collection Comparison4.1 Testing Completed in Conjunction with Electro Scan Testing; 4.2 Electro Scan Defects Compared to Water Exfiltration Rates; 4.3 Electro Scan Compared to Lateral Inspection Ratings; 4.4 Electro Scan Defects Compared to Infiltration Estimates; 4.5 Water Exfiltration Rates Compared to Infiltration Estimates; 4.6 Laterals of Interest; 4.6.1 No Recorded Infiltration or Exfiltration; 4.6.2 No Defects Noted on Lateral Inspection; 4.6.3 Highest Number of Large Defects; 4.6.4 Highest Number of Total Defects; 4.6.5 Lowest Number of Total Defects.
|
505 |
8 |
|
|a 4.6.6 No Medium or Large Defects4.6.7 Comparison of Two Nearby Laterals with Different Characteristics; 4.6.8 Comparison of Defects Discovered in Public ROW vs Private Property; Chapter 5.0: Conclusions; 5.1 Benefits of Electro Scan Testing; 5.2 Potential Drawbacks of Electro Scan Testing; 5.3 Applicability of Electro Scan Testing; 5.4 Lessons Learned; 5.5 Estimated Costs; 5.6 Additional Research Opportunities; Appendix A: Standard Operating Procedre for Electro Scan and Water Exfiltration Testing; Appendix B: Site Summaries; Appendix C: Test Results; References.
|
590 |
|
|
|a ProQuest Ebook Central
|b Ebook Central Academic Complete
|
650 |
|
0 |
|a Sewerage
|x Inspection.
|
650 |
|
6 |
|a Égouts
|x Inspection.
|
650 |
|
7 |
|a SCIENCE
|x Applied Sciences.
|2 bisacsh
|
650 |
|
7 |
|a Sewerage
|x Inspection
|2 fast
|
758 |
|
|
|i has work:
|a Sewer Lateral Electro Scan Field Verification Pilot (Text)
|1 https://id.oclc.org/worldcat/entity/E39PD33qdWF6RKfthr9TjqQGtq
|4 https://id.oclc.org/worldcat/ontology/hasWork
|
856 |
4 |
0 |
|u https://ebookcentral.uam.elogim.com/lib/uam-ebooks/detail.action?docID=3120493
|z Texto completo
|
938 |
|
|
|a EBL - Ebook Library
|b EBLB
|n EBL3120493
|
938 |
|
|
|a ProQuest MyiLibrary Digital eBook Collection
|b IDEB
|n cis27451976
|
938 |
|
|
|a YBP Library Services
|b YANK
|n 11649769
|
994 |
|
|
|a 92
|b IZTAP
|