Factors affecting the performance of primary treatment in onsite systems ; WERF report 04-Dec-7 /

Approximately 23 percent of the estimated 115 million occupied homes in the United States are served by onsite wastewater systems. The vast majority of onsite wastewater treatment systems include a septic tank, grease trap, or both for primary treatment. These units are efficient, simple, low-energy...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor principal: D'Amato, Victor A.
Formato: Electrónico eBook
Idioma:Inglés
Publicado: London : IWA Publishing, 2008.
Temas:
Acceso en línea:Texto completo

MARC

LEADER 00000cam a2200000Ma 4500
001 EBOOKCENTRAL_ocn843210247
003 OCoLC
005 20240329122006.0
006 m o d
007 cr un|nnnunaua
008 121106e200805uuenka fo 000 0 eng
040 |a Nz  |b eng  |e pn  |c UV0  |d VALIL  |d N$T  |d OCLCF  |d EBLCP  |d OCLCQ  |d DEBSZ  |d OCLCQ  |d DEBBG  |d ZCU  |d MERUC  |d ICG  |d AU@  |d OCLCQ  |d DKC  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCL 
020 |a 9781780403700  |q (electronic bk.) 
020 |a 1780403704  |q (electronic bk.) 
029 0 |a NZ1  |b 14832327 
029 1 |a AU@  |b 000062353352 
029 1 |a DEBBG  |b BV044054545 
029 1 |a DEBSZ  |b 456617698 
029 1 |a NZ1  |b 15906053 
035 |a (OCoLC)843210247 
050 4 |a TD745 
072 7 |a TQ  |2 bicssc 
072 7 |a ENV  |2 eflch 
072 7 |a TEC  |x 010000  |2 bisacsh 
082 0 4 |a 628.16  |2 22 
049 |a UAMI 
100 1 |a D'Amato, Victor A. 
245 1 0 |a Factors affecting the performance of primary treatment in onsite systems ;  |b WERF report 04-Dec-7 /  |c Victor A. D'Amato. 
260 |a London :  |b IWA Publishing,  |c 2008. 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
500 |a Electronic book text. 
500 |a Epublication based on: 9781843397816. 
520 |a Approximately 23 percent of the estimated 115 million occupied homes in the United States are served by onsite wastewater systems. The vast majority of onsite wastewater treatment systems include a septic tank, grease trap, or both for primary treatment. These units are efficient, simple, low-energy treatment units whose performance is critically important to the overall functioning of onsite wastewater systems. Regulations, industry standards, guidance materials and engineering texts vary widely and are often incomplete in their consideration of the factors that may influence primary unit performance in onsite systems. The objective of this research was therefore to identify, compile, analyze, and report on the existing body of work addressing the performance of primary treatment units in onsite wastewater systems and the factors impacting performance. Design, construction/installation, and maintenance issues were considered, with a goal of establishing what is known, what is not known and what future research is needed in this area. Over 700 sources of information were collected, with most reviewed and presented in this document -- the white paper. A bibliographic database, which can continue to be updated into the future, was developed as a companion piece to the white paper, as a tool for researchers and practitioners. 
505 0 |a Cover; Copyright; Acknowledgments; Dedication ; Abstract and Benefits; Table of Contents; List of Tables; List of Figures; List of Acronyms; Executive Summary; Background; Primary Unit Objectives; Biological Model of Septic Tank Function; Modern History and Evolution of Primary Treatment Units; Sedimentation Theory and its Relevance to Tank Design; Alternate Septic Tank Designs; Meander and Closed-Conduit, Laminar Flow Tanks; UASB-Septic Tanks and Baffled Anaerobic Reactors; Imhoff Tanks; Septic Tank Treatment Efficacy; Objectives; Nutrients; Other Wastewater Constituents. 
505 8 |a Wastewater Source and CharacteristicsFacility Type; Cluster Systems and Collection System Type; Source Separation; Septic Tank Design Characteristics; Sizing; Hydraulic Design and Characterization; Geometry; Compartmentation; Septic Tank Inlet, Outlet, and Appurtenances; Food Service Facilities and Grease Trap Design; Seasonal/Temperature Effects on Biology; Sludge/Scum Accumulation and Removal; Use of Additives; Water Softeners; Garbage Grinders; Inspection, Operation and Maintenance; Performance Monitoring and Troubleshooting; Sampling; Venting; Tank Construction and Installation. 
505 8 |a Existing Tank StandardsState Regulations; Industry Standards; Research Recommendations; Types of Studies; Common Study Design Limitations; Existing Data; Conclusions; Additional Resources; Glossary ; References; Appendix A: Existing Tank Standards ; Appendix B: History/Evolution of Primary Treatment Units in Decentralized Systems. 
590 |a ProQuest Ebook Central  |b Ebook Central Academic Complete 
650 0 |a Sewage  |x Purification. 
650 6 |a Eaux usées  |x Épuration. 
650 7 |a SCIENCE  |x Applied Sciences.  |2 bisacsh 
650 7 |a TECHNOLOGY & ENGINEERING  |x Environmental  |x General.  |2 bisacsh 
650 7 |a Sewage  |x Purification  |2 fast 
758 |i has work:  |a Factors Affecting the Performance of Primary Treatment in Onsite Systems ; WERF Report 04C-7 (Text)  |1 https://id.oclc.org/worldcat/entity/E39PCYfwPWJ3dTJJGb896kt8vd  |4 https://id.oclc.org/worldcat/ontology/hasWork 
776 0 8 |i Erscheint auch als:  |n Druck-Ausgabe  |a Factors affecting the performance of primary treatment in decentralized wastewater systems .  |t Research digest 
856 4 0 |u https://ebookcentral.uam.elogim.com/lib/uam-ebooks/detail.action?docID=3120815  |z Texto completo 
938 |a EBL - Ebook Library  |b EBLB  |n EBL3120815 
938 |a EBSCOhost  |b EBSC  |n 719426 
994 |a 92  |b IZTAP