|
|
|
|
LEADER |
00000nam a22000005i 4500 |
001 |
978-981-10-1572-4 |
003 |
DE-He213 |
005 |
20220422145802.0 |
007 |
cr nn 008mamaa |
008 |
160621s2016 si | s |||| 0|eng d |
020 |
|
|
|a 9789811015724
|9 978-981-10-1572-4
|
024 |
7 |
|
|a 10.1007/978-981-10-1572-4
|2 doi
|
050 |
|
4 |
|a TK1001-1841
|
072 |
|
7 |
|a THR
|2 bicssc
|
072 |
|
7 |
|a TEC031000
|2 bisacsh
|
072 |
|
7 |
|a THR
|2 thema
|
082 |
0 |
4 |
|a 621.31
|2 23
|
100 |
1 |
|
|a Makwana, Vijay H.
|e author.
|4 aut
|4 http://id.loc.gov/vocabulary/relators/aut
|
245 |
1 |
0 |
|a Transmission Line Protection Using Digital Technology
|h [electronic resource] /
|c by Vijay H. Makwana, Bhavesh R. Bhalja.
|
250 |
|
|
|a 1st ed. 2016.
|
264 |
|
1 |
|a Singapore :
|b Springer Nature Singapore :
|b Imprint: Springer,
|c 2016.
|
300 |
|
|
|a XIX, 167 p. 62 illus., 1 illus. in color.
|b online resource.
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
347 |
|
|
|a text file
|b PDF
|2 rda
|
490 |
1 |
|
|a Energy Systems in Electrical Engineering,
|x 2199-8590
|
505 |
0 |
|
|a Chapter 1: Introduction -- Chapter 2: Distance Relaying Algorithm for a Single Line-to-Ground Fault on Single Infeed Transmission Lines -- Chapter 3: Digital Distance Relaying Scheme for Compensation of High Resistance Faults on Double Infeed Transmission Lines -- Chapter 4: Digital Distance Relaying Scheme for Parallel Transmission Lines During Inter-Circuit Faults -- Chapter 5: Digital Distance Relaying Scheme for Series Compensated Parallel Lines During Simultaneous Open Conductor & Ground Fault -- Chapter 6: Digital Distance Relaying Scheme for Series Compensated Parallel Transmission Lines During Inter-Circuit Faults -- Chapter 7: Digital Distance Relaying Scheme for Phase Faults on Double Infeed Transmission Lines -- Appendix(A-F).
|
520 |
|
|
|a This book develops novel digital distance relaying schemes to eliminate the errors produced by the conventional digital distance relays while protecting power transmission lines against different types of faults. These include high resistance ground faults on single infeed transmission lines; high resistance ground faults on double infeed transmission lines; simultaneous open conductor and ground fault on double infeed transmission lines; inter-circuit faults on parallel transmission lines; simultaneous open conductor and ground fault on series compensated parallel transmission lines; inter-circuit faults on series compensated parallel transmission lines; and phase faults on series compensated double infeed transmission lines. This monograph also details suggestions for further work in the area of digital protection of transmission lines. The contents will be useful to academic as well as professional researchers working in transmission line protection. .
|
650 |
|
0 |
|a Electric power production.
|
650 |
|
0 |
|a Energy storage.
|
650 |
1 |
4 |
|a Electrical Power Engineering.
|
650 |
2 |
4 |
|a Mechanical Power Engineering.
|
650 |
2 |
4 |
|a Mechanical and Thermal Energy Storage.
|
700 |
1 |
|
|a Bhalja, Bhavesh R.
|e author.
|4 aut
|4 http://id.loc.gov/vocabulary/relators/aut
|
710 |
2 |
|
|a SpringerLink (Online service)
|
773 |
0 |
|
|t Springer Nature eBook
|
776 |
0 |
8 |
|i Printed edition:
|z 9789811015717
|
776 |
0 |
8 |
|i Printed edition:
|z 9789811015731
|
776 |
0 |
8 |
|i Printed edition:
|z 9789811093906
|
830 |
|
0 |
|a Energy Systems in Electrical Engineering,
|x 2199-8590
|
856 |
4 |
0 |
|u https://doi.uam.elogim.com/10.1007/978-981-10-1572-4
|z Texto Completo
|
912 |
|
|
|a ZDB-2-ENE
|
912 |
|
|
|a ZDB-2-SXEN
|
950 |
|
|
|a Energy (SpringerNature-40367)
|
950 |
|
|
|a Energy (R0) (SpringerNature-43717)
|