Cargando…

Open, Laparoscopic and Robotic Hepatic Transection Tools and Methods /

Bleeding from the liver surface during hepatic transection is one of the main factors affecting mortality and morbidity of liver resection. For this reason, numerous devices have been developed that employ a variety of techniques to minimize parenchymal damage and so improve the safety of resection....

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor Corporativo: SpringerLink (Online service)
Otros Autores: Di Carlo, Isidoro (Editor )
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Milano : Springer Milan : Imprint: Springer, 2012.
Edición:1st ed. 2012.
Temas:
Acceso en línea:Texto Completo

MARC

LEADER 00000nam a22000005i 4500
001 978-88-470-2622-3
003 DE-He213
005 20220116014105.0
007 cr nn 008mamaa
008 121026s2012 it | s |||| 0|eng d
020 |a 9788847026223  |9 978-88-470-2622-3 
024 7 |a 10.1007/978-88-470-2622-3  |2 doi 
050 4 |a RD1-811 
072 7 |a MN  |2 bicssc 
072 7 |a MED085000  |2 bisacsh 
072 7 |a MN  |2 thema 
082 0 4 |a 617  |2 23 
245 1 0 |a Open, Laparoscopic and Robotic Hepatic Transection  |h [electronic resource] :  |b Tools and Methods /  |c edited by Isidoro Di Carlo. 
250 |a 1st ed. 2012. 
264 1 |a Milano :  |b Springer Milan :  |b Imprint: Springer,  |c 2012. 
300 |a XVIII, 164 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
505 0 |a Preface -- Introduction -- Liver anatomy -- Bisbane liver classification.-Section 1: Open method for liver transection -- Ultrasonically activated device for parenchymal division during open hepatectomy -- Liver transaction using the LigaSure sealing system -- Blocking intrahepatic inflow and backflow using Chang's needle during hepatic resection: Chang's maneuver -- Liver transection using a vascular stapler: a review -- Liver resection with a bipolar radiofrequency device: Habib 4X -- Open hepatic parenchymal transection using ultrasonic dissection and bipolar coagulation -- Use of a dissecting sealer for hepatic resection -- The use of water-jet dissection in open and laparoscopic liver resection -- Usefulness of the Kelly clamp crushing technique during hepatic resection -- "Curettage and aspiration dissection technique" using Peng's multifunctional operative dissector (PMOD) for liver resection -- Liver resection using microwave tissue coagulation -- Section 2: Laparoscopic liver transection -- Application of devices for safe laparoscopic hepatectomy -- Parenchymal transection using saline-enhanced electrosurgery -- Laparosocpic liver resection using a bipolar vessel-sealing device -- The Laparoscopic Habib 4X -- Laparoscopic liver resection using a stapler device -- Section 3: Robotic liver transection tools and methods. 
520 |a Bleeding from the liver surface during hepatic transection is one of the main factors affecting mortality and morbidity of liver resection. For this reason, numerous devices have been developed that employ a variety of techniques to minimize parenchymal damage and so improve the safety of resection. This book describes all the devices that are currently available for hepatic transection via open, laparoscopic, and robotic approaches. Procedures are explained and illustrated step by step using informative color figures and photographs. This landmark reference in the field will be an ideal guide for liver surgeons as well as a valuable tool for students, residents, and general surgeons. 
650 0 |a Surgery. 
650 0 |a Oncology. 
650 1 4 |a Surgery. 
650 2 4 |a Oncology. 
650 2 4 |a General Surgery. 
700 1 |a Di Carlo, Isidoro.  |e editor.  |4 edt  |4 http://id.loc.gov/vocabulary/relators/edt 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer Nature eBook 
776 0 8 |i Printed edition:  |z 9788847026230 
776 0 8 |i Printed edition:  |z 9788847026216 
776 0 8 |i Printed edition:  |z 9788847039131 
856 4 0 |u https://doi.uam.elogim.com/10.1007/978-88-470-2622-3  |z Texto Completo 
912 |a ZDB-2-SME 
912 |a ZDB-2-SXM 
950 |a Medicine (SpringerNature-11650) 
950 |a Medicine (R0) (SpringerNature-43714)