Physical and Statistical Models for Steam Generator Clogging Diagnosis

Clogging of steam generators in nuclear power plants is a highly sensitive issue in terms of performance and safety and this book proposes a completely novel methodology for diagnosing this phenomenon. It demonstrates real-life industrial applications of this approach to French steam generators and...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autor principal: Girard, Sylvain (Autor)
Autor Corporativo: SpringerLink (Online service)
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Cham : Springer International Publishing : Imprint: Springer, 2014.
Edición:1st ed. 2014.
Colección:SpringerBriefs in Applied Sciences and Technology,
Temas:
Acceso en línea:Texto Completo

MARC

LEADER 00000nam a22000005i 4500
001 978-3-319-09321-5
003 DE-He213
005 20220118015346.0
007 cr nn 008mamaa
008 140726s2014 sz | s |||| 0|eng d
020 |a 9783319093215  |9 978-3-319-09321-5 
024 7 |a 10.1007/978-3-319-09321-5  |2 doi 
050 4 |a TK9001-9401 
072 7 |a THK  |2 bicssc 
072 7 |a TEC028000  |2 bisacsh 
072 7 |a THK  |2 thema 
082 0 4 |a 621.48  |2 23 
100 1 |a Girard, Sylvain.  |e author.  |4 aut  |4 http://id.loc.gov/vocabulary/relators/aut 
245 1 0 |a Physical and Statistical Models for Steam Generator Clogging Diagnosis  |h [electronic resource] /  |c by Sylvain Girard. 
250 |a 1st ed. 2014. 
264 1 |a Cham :  |b Springer International Publishing :  |b Imprint: Springer,  |c 2014. 
300 |a IX, 97 p. 76 illus., 42 illus. in color.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a SpringerBriefs in Applied Sciences and Technology,  |x 2191-5318 
505 0 |a 1 Introduction -- 2 Clogging of recirculating nuclear steam generators -- 3 State of the art of clogging diagnosis -- 4 Steam generator physical model -- 5 Sensitivity analysis -- 6 Sliced inverse regression -- 7 Statistical analysis of the physical model -- 8 New diagnosis method -- 9 Synthesis and usage recommendation -- Appendix A Characteristics of the type 51B steam generator. 
520 |a Clogging of steam generators in nuclear power plants is a highly sensitive issue in terms of performance and safety and this book proposes a completely novel methodology for diagnosing this phenomenon. It demonstrates real-life industrial applications of this approach to French steam generators and applies the approach to operational data gathered from French nuclear power plants. The book presents a detailed review of in situ diagnosis techniques and assesses existing methodologies for clogging diagnosis, whilst examining their limitations. It also addresses numerical modelling of the dynamic behaviour of steam generators and provides a thorough analysis of statistical methods for sensitivity analysis and dimension reduction. Steam generators are heat exchangers found in nuclear power plants and over time they become increasingly clogged by iron oxides. This clogging then hampers the flow inside steam generators and compromises their mechanical integrity, which hinders performance and safety. This book is intended for nuclear safety specialists, nuclear performance engineers and researchers and postgraduate students working on heat exchanger modeling and computational engineering. 
650 0 |a Nuclear engineering. 
650 0 |a Numerical analysis. 
650 0 |a Thermodynamics. 
650 0 |a Heat engineering. 
650 0 |a Heat transfer. 
650 0 |a Mass transfer. 
650 1 4 |a Nuclear Energy. 
650 2 4 |a Numerical Analysis. 
650 2 4 |a Engineering Thermodynamics, Heat and Mass Transfer. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer Nature eBook 
776 0 8 |i Printed edition:  |z 9783319093222 
776 0 8 |i Printed edition:  |z 9783319093208 
830 0 |a SpringerBriefs in Applied Sciences and Technology,  |x 2191-5318 
856 4 0 |u https://doi.uam.elogim.com/10.1007/978-3-319-09321-5  |z Texto Completo 
912 |a ZDB-2-ENE 
912 |a ZDB-2-SXEN 
950 |a Energy (SpringerNature-40367) 
950 |a Energy (R0) (SpringerNature-43717)