Cargando…

Biopotential Readout Circuits for Portable Acquisition Systems

In recent years, we have witnessed a revolutionary change in biomedical signal monitoring. The traditional way of using bulky instruments is being replaced by portable and even wearable acquisition systems with wireless data transmission that will enable many non-clinical applications that rely on b...

Descripción completa

Detalles Bibliográficos
Clasificación:Libro Electrónico
Autores principales: Yazicioglu, Refet Firat (Autor), van Hoof, Chris (Autor), Puers, Robert (Autor)
Autor Corporativo: SpringerLink (Online service)
Formato: Electrónico eBook
Idioma:Inglés
Publicado: Dordrecht : Springer Netherlands : Imprint: Springer, 2009.
Edición:1st ed. 2009.
Colección:Analog Circuits and Signal Processing,
Temas:
Acceso en línea:Texto Completo

MARC

LEADER 00000nam a22000005i 4500
001 978-1-4020-9093-6
003 DE-He213
005 20220114233205.0
007 cr nn 008mamaa
008 100301s2009 ne | s |||| 0|eng d
020 |a 9781402090936  |9 978-1-4020-9093-6 
024 7 |a 10.1007/978-1-4020-9093-6  |2 doi 
050 4 |a TK7867-7867.5 
072 7 |a TJFC  |2 bicssc 
072 7 |a TEC008010  |2 bisacsh 
072 7 |a TJFC  |2 thema 
082 0 4 |a 621.3815  |2 23 
100 1 |a Yazicioglu, Refet Firat.  |e author.  |4 aut  |4 http://id.loc.gov/vocabulary/relators/aut 
245 1 0 |a Biopotential Readout Circuits for Portable Acquisition Systems  |h [electronic resource] /  |c by Refet Firat Yazicioglu, Chris van Hoof, Robert Puers. 
250 |a 1st ed. 2009. 
264 1 |a Dordrecht :  |b Springer Netherlands :  |b Imprint: Springer,  |c 2009. 
300 |a XV, 164 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a Analog Circuits and Signal Processing,  |x 2197-1854 
505 0 |a to Biopotential Acquisition -- 24-Channel EEG Readout Front-End ASIC -- Biopotential Readout Front-End ASICs -- A Complete Biopotential Acquisition ASIC -- Wireless Biopotential Acquisition Systems -- Conclusions. 
520 |a In recent years, we have witnessed a revolutionary change in biomedical signal monitoring. The traditional way of using bulky instruments is being replaced by portable and even wearable acquisition systems with wireless data transmission that will enable many non-clinical applications that rely on biomedical signal monitoring. The main driver applications are early-warning systems, wellness, comfort and sports monitoring, brain-computer interfaces, gaming and entertainment. The common requirements from all these applications are miniature size, unobtrusiveness, high signal quality, and long-term power autonomy. This requires ultra-low-power and miniature SiP/SoC biomedical signal acquisition systems. Biopotential Readout Circuits for Portable Acquisition Systems describes one of the main building blocks of such miniaturized biomedical signal acquisition systems. The focus of this book is on the implementation of low-power and high-performance integrated circuit building blocks that can be used to extract biopotential signals from conventional biopotential electrodes. New instrumentation amplifier architectures are introduced and their design is described in detail. These amplifiers are used to implement complete acquisition demonstrator systems that are a stepping stone towards practical miniaturized and low-power systems. 
650 0 |a Electronic circuits. 
650 0 |a Biomedical engineering. 
650 1 4 |a Electronic Circuits and Systems. 
650 2 4 |a Biomedical Engineering and Bioengineering. 
700 1 |a van Hoof, Chris.  |e author.  |4 aut  |4 http://id.loc.gov/vocabulary/relators/aut 
700 1 |a Puers, Robert.  |e author.  |4 aut  |4 http://id.loc.gov/vocabulary/relators/aut 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer Nature eBook 
776 0 8 |i Printed edition:  |z 9789048180707 
776 0 8 |i Printed edition:  |z 9781402091025 
776 0 8 |i Printed edition:  |z 9781402090929 
830 0 |a Analog Circuits and Signal Processing,  |x 2197-1854 
856 4 0 |u https://doi.uam.elogim.com/10.1007/978-1-4020-9093-6  |z Texto Completo 
912 |a ZDB-2-ENG 
912 |a ZDB-2-SXE 
950 |a Engineering (SpringerNature-11647) 
950 |a Engineering (R0) (SpringerNature-43712)