|
|
|
|
LEADER |
00000nam a22000005i 4500 |
001 |
978-0-85729-856-0 |
003 |
DE-He213 |
005 |
20220118195835.0 |
007 |
cr nn 008mamaa |
008 |
110725s2011 xxk| s |||| 0|eng d |
020 |
|
|
|a 9780857298560
|9 978-0-85729-856-0
|
024 |
7 |
|
|a 10.1007/978-0-85729-856-0
|2 doi
|
050 |
|
4 |
|a TK1001-1841
|
072 |
|
7 |
|a THR
|2 bicssc
|
072 |
|
7 |
|a TEC031000
|2 bisacsh
|
072 |
|
7 |
|a THR
|2 thema
|
082 |
0 |
4 |
|a 621.31
|2 23
|
100 |
1 |
|
|a Bartnik, Ryszard.
|e author.
|0 (orcid)0000-0002-0480-8651
|1 https://orcid.org/0000-0002-0480-8651
|4 aut
|4 http://id.loc.gov/vocabulary/relators/aut
|
245 |
1 |
0 |
|a Conversion of Coal-Fired Power Plants to Cogeneration and Combined-Cycle
|h [electronic resource] :
|b Thermal and Economic Effectiveness /
|c by Ryszard Bartnik, Zbigniew Buryn.
|
250 |
|
|
|a 1st ed. 2011.
|
264 |
|
1 |
|a London :
|b Springer London :
|b Imprint: Springer,
|c 2011.
|
300 |
|
|
|a X, 154 p.
|b online resource.
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
347 |
|
|
|a text file
|b PDF
|2 rda
|
505 |
0 |
|
|a 1. Introduction -- 2. Selection of Optimal Heating Structures for Modernization of Coal-Fired Power Stations to Cogeneration -- 3. Mathematical Model of a Power Unit with Rated Capacity of 370 MW After Its Modernization to Cogeneration and Combined-Cycle -- 4. Algorithm for the Calculation of an Optimum Structure of Heat Exchangers for the Modernization of a 370 MW Power Unit to Combined Heat and Power Cycle -- 5. Testing Calculations of the Mathematical Model of a Power Unit -- 6. Thermodynamic Analysis of a Combined Heat and Power Unit Using Extractions A2, A3 and Crossoverpipe IP-LP for Heater Supply -- 7. Economic Efficiency of a Power Unit Adapted to Cogeneration -- 8. Technical and Economical Effectiveness of Modernization 370 MW Power Unit Repowered by Gas Turbine with Their Modernization to Cogeneration -- 9. Technical and Economical Effectiveness of 370 MW Power Unit Repowered by Gas Turbine in Parallel System -- 10. Summary and Final Conclusions.
|
520 |
|
|
|a Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle presents the methodology, calculation procedures and tools used to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms. The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.
|
650 |
|
0 |
|a Electric power production.
|
650 |
|
0 |
|a Cogeneration of electric power and heat.
|
650 |
|
0 |
|a Fossil fuels.
|
650 |
|
0 |
|a Thermodynamics.
|
650 |
|
0 |
|a Heat engineering.
|
650 |
|
0 |
|a Heat transfer.
|
650 |
|
0 |
|a Mass transfer.
|
650 |
1 |
4 |
|a Electrical Power Engineering.
|
650 |
2 |
4 |
|a Mechanical Power Engineering.
|
650 |
2 |
4 |
|a Fossil Fuel.
|
650 |
2 |
4 |
|a Thermodynamics.
|
650 |
2 |
4 |
|a Engineering Thermodynamics, Heat and Mass Transfer.
|
700 |
1 |
|
|a Buryn, Zbigniew.
|e author.
|4 aut
|4 http://id.loc.gov/vocabulary/relators/aut
|
710 |
2 |
|
|a SpringerLink (Online service)
|
773 |
0 |
|
|t Springer Nature eBook
|
776 |
0 |
8 |
|i Printed edition:
|z 9781447159513
|
776 |
0 |
8 |
|i Printed edition:
|z 9780857298553
|
776 |
0 |
8 |
|i Printed edition:
|z 9780857298577
|
856 |
4 |
0 |
|u https://doi.uam.elogim.com/10.1007/978-0-85729-856-0
|z Texto Completo
|
912 |
|
|
|a ZDB-2-ENG
|
912 |
|
|
|a ZDB-2-SXE
|
950 |
|
|
|a Engineering (SpringerNature-11647)
|
950 |
|
|
|a Engineering (R0) (SpringerNature-43712)
|